NEC EXP801 Maintenance Manual page 149

Table of Contents

Advertisement

Chapter 3 Appendix
(3) Error messages on a virtual LCD
You can confirm the error messages by using the EXPRESSSCOPE Engine 3 web browser window. For details,
see EXPRESSSCOPE Engine 3 User's Guide.
The table below shows the error messages displayed on upper and lower lines, cause, and action.
If the same error appears even if the action is performed, contact your sales representative.
Messages displayed on an upper LCD line
BIOS Message
on Upper LCD Line
XX POST Started...
XX BIOS Rev YYYY
POST Completed
Successfully
POST ERROR XXXX
No Available Memory in
System
Error Pause in POST
Entering BIOS SETUP MENU Starting up BIOS SETUP MENU.
Waiting for normal
temperature
BIOS Recovery Running
BIOS Updater Running
System Configuration
change is detected
PCI Bus System Error 1 A system error was detected in
PCI Bus Parity Error 1 A parity error was detected in PCI
CPUx_DIMMx Correctable
Error (x: DIMM number)
Memory DIMM Sparing
Fail-over on CPUx (x:
CPU socket number)
Memory Mirroring
Fail-over on CPUx (x:
socket number)
Cause
Displayed while POST is running.
"XX" denotes POST code that is
running.
Displayed while POST is running.
"XX" denotes POST code that is
running, and "YYYY" denotes
system BIOS version.
POST completes normally.
Error XXXX occurred during
POST.
No available memory is
implemented.
POST detected an error and
paused.
A temperature abnormality was
detected inside the server.
BIOS recovery is in progress.
BIOS update is in progress.
The CPU or memory configuration
has changed since the previous
startup.
PCI bus.
bus.
A frequent occurrence of
correctable memory error was
detected.
Memory Sparing feature failed
over to standby memory.
Memory Mirroring feature failed
over to standby memory.
Express5800/R120g-1M, R120g-2M Maintenance Guide
Message displayed on
upper LCD line
Message sent from BIOS
Message displayed on lower
LCD line
Message sent from BMC
Action
This is not an error.
Check the message displayed on LCD, and take an
appropriate action.
Make sure that the memory is correctly
implemented.
Check the message displayed on LCD, and take an
appropriate action.
This is not an error. This message will disappear
when SETUP operation is completed.
Lower the room temperature or turn off the power to
cool the server to room temperature before starting
up the server. If this abnormality continues to occur,
check if a fan has failed.
This is not an error. Wait until BIOS update is
completed.
If this message appears even when no configuration
change has been made, contact your sales
representative
Contact your sales representative.
1. POST Error Message