15 Network connection

Sealing material
▶ The sealing material is not included in the scope of deliv-
ery.
Only use appropriate sealing material.
1. Keep thread sealant ready.
2. Carry out preparations for installation (see chapter "Pre-
paring for installation").
3. Screw the threaded connections into the pipe in accord-
ance with valid standards.
4. Screw the body of the product onto the piping using ap-
propriate thread sealant.
5. Re-attach or reactivate all safety and protective devices.

14.6 Installation with threaded spigots

Fig. 11: Threaded spigots
Thread sealant
▶ The thread sealant is not included in the scope of deliv-
ery.
Only use appropriate thread sealant.
1. Keep thread sealant ready.
2. Carry out preparations for installation (see chapter "Pre-
paring for installation").
3. Screw the pipe into the threaded connection of the valve
body in accordance with valid standards.
ð Use appropriate thread sealant.
4. Re-attach or reactivate all safety and protective devices.

14.7 Installation with flanged connection

Fig. 12: Flanged connection
Sealing material
▶ The sealing material is not included in the scope of deliv-
ery.
Only use appropriate sealing material.
GEMÜ 649 eSyDrive
NOTICE
NOTICE
NOTICE
Connector elements
▶ The connector elements are not included in the scope of
delivery.
Only use connector elements made of approved materi-
als.
Observe permissible tightening torque of the bolts.
1. Keep sealing material ready.
2. Carry out preparations for installation (see chapter "Pre-
paring for installation").
3. Ensure clean, undamaged sealing surfaces on the connec-
tion flanges.
4. Align flanges carefully before installing them.
5. Clamp the product centrally between the piping with
flanges.
6. Centre the gaskets.
7. Connect the valve flange and the piping flange using ap-
propriate sealing materials and matching bolting.
8. Use all flange holes.
9. Tighten the bolts diagonally.
10. Re-attach or reactivate all safety and protective devices.
15 Network connection

15.1 Network settings

The network interface has the following default settings:
IP address: 192.168.2.1
Subnet screen: 255.255.252.0
The default settings can be changed. See the eSy-Web operat-
ing instructions.

15.2 Connecting the network

1. Connect the network plug and cables with the electrical
connection X2 of the product.
2. Change the IP address using the web server.

15.3 Resetting the network settings

1. Ensure that the "ON-Site" DIP switch 8 is not in the "ON"
position.
2. Press and hold down the "OPEN" button 9 for at least 8 s.
ð LED 1 flashes fast in blue.
3. Press the "INIT/CLOSE" button 10.
ð Network settings are reset in the default settings.