25294 00 - SN SI550DOm/600DOm
Connect to the gas supply
The inlet to the cooker is
internal situated at the rear right corner.
Fit the bayonet connection. This should
be located so as to ensure that the
flexible connector hose does not kink.
Use a 900mm - 1125mm length of
flexible connector.
Ensure that all pipe work is of the correct
rating for both size and temperature.
Flexible connections should comply
with BS 669. Parts of the appliance
likely to come into
flexible connector have a temperature
rise of less than 70˚C.
After installation, make sure all
connections are gas sound.
23/10/2002
12:39
Installation Instructions

Commissioning

" BSP
1
2
Burner aeration
All burners have fixed aeration and no
adjustment is possible.
Pressure setting
G20 Natural Gas @ 20 mbar
Pressure test point
Use the oven injector.
Grill - Open the top compartment
door before igniting the grill. Push in
contact with a
the control knob and turn clockwise to
the grill setting., wait a second before
pressing the ignition switch or holding
a lighted match or taper to the burner.
Hob - Turn the control knob to the
ON
pressing the ignition switch or holding
a lighted match or taper to the burner.
Ovens - Open the oven door. Turn
the control to the
press the ignition switch,or holding a
lighted match or taper to the burner. The
burner operates at a low rate for up to
60 seconds until the flame supervision
device opens & full gas rate is obtained.
Before leaving the installation
1. Place all the loose parts of the
2. Show the customer how to operate
24
Page 26
position, wait a second before
position and
FULL ON
cooker into position.
the cooker and give them this
handbook. Thank you.
FULL