Pressure Setting; G20 Natural Gas @ 20 Mbar; G30 Butane @ 28-30 Mbar; G31 Propane @ 37 Mbar - STOVES 1000DFDL User & Installation Instructions Manual

Dual fuel range cooker for natural gas models and lp gas models
Table of Contents

Advertisement

Introduction

Thank
you
for
choosing
British built appliance by Stoves
We hope the following information
will help you to quickly familiarise
yourself with the features of the
appliance, and to use it successfully
and safely.
Our policy is one of constant
development and improvement. Strict
accuracy of illustrations and specifications
is not guaranteed.
Modification to
design and materials may be necessary
subsequent to publication.
This appliance must be installed in
accordance with the regulations in
force, and only in a well ventilated
space.
Read the instructions before
installing or using this appliance.
Your 1st Year Guarantee
To fulfil the conditions of your guarantee,
this appliance must be correctly
installed and operated, in accordance
with these instructions, and only be
used for normal domestic purposes.
Please note that the guarantee, and
Service availability, only apply to the
UK and Republic of Ireland.
Before using the appliance for
the first time, remove any protective
polythene film and wash the oven
shelves and furniture in hot soapy
water, to remove their protective
coating of oil. Even so, when you first
turn on the oven or grill you may
notice a smell and some smoke.
a
Your new appliance is designed to be
installed free-standing or flush to base
units.
The User's Section in this handbook
covers the operation of the ovens,
grill, hotplate and griddle (if supplied),
but to help you make the most of your
range cooker, we have produced the
accompanying
"Cooking
which gives more details of its features
and benefits.
Gas & Electrical connection
Please refer to installation instructions
for the Gas & Electrical Safety Regulations
and the Ventilation Requirements.
In your own interest, and that of safety,
it is the law that all gas appliances be
installed by competent persons who
will ensure that the installation is in
accordance with "The Gas Safety
(Installation & Use) Regulations 1994",
& the "The Gas Safety (Installation &
Use) (Amendment) Regulations 1996".
Failure
to
comply
with
Regulations is a criminal offence.
Corgi registered installers undertake to
work to satisfactory standards.
Disconnection of gas and electric
appliances should always be carried
out by competent persons.
Warning: This appliance must be
earthed.
2
Connect to the gas supply
The inlet to the cooker is
internal situated at the rear centre.
Use a 900mm - 1125mm length of
flexible connector.
Ensure that all pipe work is of the
correct rating for both size and
temperature.
Natural Gas - Flexible connections
Guide"
should comply with BS 669. Parts of
the appliance likely to come into
contact with a flexible connector have
a temperature rise of less than 70˚C.
LP Gas - For flexible connections, use
a bayonet type hose, suitable for use
on LP Gas up to 50 mbar pressure rise
and 70˚C temperature rise.
flexible hose should be coloured black
with a red stripe, band or label. If in
doubt, contact your supplier.
After installation, make sure all
connections are gas sound.
Important: - ensure that you route
all mains and electrical cables and
flexible tubing well clear of any
these
adjacent heat source.
Installation Instructions
Commissioning
" BSP
1
2
Burner aeration
All burners have fixed aeration and no
adjustment is possible.

Pressure setting

G20 Natural Gas @ 20 mbar

G30 Butane @ 28-30 mbar

G31 Propane @ 37 mbar

Ignition
All burners are ignited by pressing the
ignition switch on the facia. When the
burner has lit release the ignition
switch.
Turn the tap to the
position, wait a second before
The
pressing the ignition switch.
Before leaving the installation
1. Place all the loose parts of the
cooker into position.
2. Show the customer how to operate
the cooker and give them this
handbook.
Thank you.