Technical Data - STOVES Newhome SI550DOm User & Installation Instructions Manual

Freestanding double oven gas cookers
Table of Contents

Advertisement

25294 00 - SN SI550DOm/600DOm
Data badge
Lower part of front frame
Type of gas
This cooker must only be used with Natural
Gas only, as specified on the appliance
data badge.
Gas category
Natural Gas - I
2H
Pressure setting
G20 Natural Gas @ 20 mbar
Pressure test point
Use the oven injector
Aeration
Fixed
Appliance class
Class 1, freestanding
Countries of destination
GB - Great Britain, IE - Ireland
Gas
Burner
Natural
Grill
Gas
Hob - LHF (auxiliary)
Hob - LHR & RHR (semi rapid)
Hob - RHF (rapid)
Main Oven
Top Oven
Maximum heat input
23/10/2002
12:39
Page 27

Technical Data

Grill
Grill burner is surface combustion type.
Spark gaps 3 - 4mm.
Hob
Burners have burner heads and caps
which are removable for cleaning.
Concealed electrodes to each burner.
Ovens
Oven burners are sheet steel, with pierced
ports in stainless steel flame strip. Spark
Gap: 3 - 4mm.
Expansion type. Thermostat phial: Front
centre of oven roof.
Electrical supply
220 - 240V ~ 50Hz
Spark generator: Mains operated 7 outlet
controlled by a single push button switch at the
left hand side of the facia to individual
electrodes.
Warning: This cooker must be earthed.
Nominal Rate Qn
2.4kW
1.0kW
2.0kW
3.0kW
2.5kW
1.75kW
∑Qn 12.9kW
25
Flame supervision:
Injector Size
1.15 mm
77
104
130
180 Amal
110 Amal
-