Connect to the gas supply

The inlet to the cooker is
situated at the rear centre.
Fit the bayonet connection.
should be located so as to ensure the
flexible connector hose does not kink.
Use a 900mm - 1125mm length of
flexible connector.
Natural Gas - Flexible connections
should comply with BS 669. Parts of
the appliance likely to come into con-
tact with a
flexible connector have a
temperature rise of less than 70˚C.
LP Gas - For flexible connections, use
a bayonet type hose, suitable for use
on LP Gas up to 50 mbar pressure rise
and 70˚C temperature rise.
flexible hose should be coloured black
with a red stripe, band or label. If in
doubt, contact your supplier.
After installation, make sure all
connections are gas sound.
Important: ensure that you route all
mains electrical cables and flexible
tubing well clear of any adjacent heat
source.
Ensure that all pipework is of the correct
rating for both size and temperature.

INSTALLATION INSTRUCTIONS

" RP internal
1
2

Commissioning

Burner aeration
This
All burners have fixed aeration and no
adjustment is possible.
Pressure setting
G20 Natural gas @ 20 mbar
G30 Butane @ 28-30 mbar
G31 Propane @ 37 mbar
Ignition
All burners are ignited by pressing the
ignition switch on the facia. When
the burner has lit release the ignition
The
switch. Turn the tap to the
position, wait a
pressing the ignition switch.
Before leaving the installation
1. Place all the loose parts of the
cooker into position.
2. Show the customer how to operate
the cooker and give them this
handbook.
Thank you.