7.0 - Light signals

Below is the meaning of the light signals provided by the RTC R1 board (see electronic board on page 13).
POWER LED (GREEN)
LED STATUS
OFF
FLASHING SHORTLY
FLASHING FAST
ON WITH SHORT SHUTDOWN
ON
LA STATUS LED (TWO-COLOUR)
LED COLOUR
LED STATUS
-
RED
GREEN
ORANGE
ORANGE
FLASHING
ERROR LED (RED)
NUMBER OF
DESCRIPTION
FLASHES
NONE
No fault detected.
High rising actuator absorption (retractable unit closing).
The signal is triggered after the system has made three attempts to rise in the presence of mechanical friction above the set
1
threshold. The problem can be caused by a foreign body entering the mechanism, the boat sailing at high speed, or mechanical
problems with the retractable thruster and its hatch.
Fuse open.
2
A current absorption greater than 10A has occurred. The problem may occur if there is a short circuit or overload on the actuator
power line. Check the wiring of the power lines from the board to the actuator or the absorption of the actuator itself.
Abnormal limit switch condition.
3
The problem is reported if the board detects a fault on the limit switches (both activated). Check the power line wiring from the
board to the limit switches and their operation.
Actuator control line interruption.
4
The problem is reported if the board detects an interruption in the actuator control power line. Check the wiring of the power
lines from the board to the actuator.
Actuator movement timeout tripped.
5
The problem is reported if the movement imparted to the actuator is not carried out within a period of 15 seconds.
Incorrect dip-switch configuration.
6
The problem is reported if the dip-switch positions are not set correctly.
High lowering actuator absorption (retractable unit opening).
The signal is triggered after the system has made three attempts to lower in the presence of a mechanical friction above the set
7
threshold. The problem can be caused by a foreign body entering the mechanism, the boat sailing at high speed, or mechanical
problems with the retractable thruster and its hatch.
High absorption of motor reversing contactor control output.
The problem is reported if the board detects a short circuit or overload on the motor control power line. Check the wiring of the
8
power lines from the board to the motor and the absorption of the reversing contactor/motor unit installed on the retractable
thruster.
Motor thermal cut-out tripped.
The problem is reported if the thermal cut-out of the motor has tripped.
Wait for it to cool down.
9
Interruption of motor reversing contactor control output connection.
The problem is reported if the board detects an interruption in the motor control power line.
Check the wiring of the power lines from the board to the reversing contactor/motor unit installed on the retractable thruster.
20
DESCRIPTION
Board not powered
Board powered but control not enabled
Board powered and active manual actuator movement mode
Board powered but control not enabled and link active with CAN control station
Board powered and control enabled (TCD or CAN station).
DESCRIPTION
OFF
With board powered, active manual actuator movement mode and limit switch fault present
ON
Retractable unit closed (active LSC limit switch)
ON
Retractable unit open (active LSO limit switch)
ON
Retractable unit neither open nor closed (LSC and LSO limit switches not active)
Retractable unit neither open nor closed (LSC and LSO limit switches not active) and linear actuator in
motion.
QUICK BTR Series INSTALLATION AND USER'S MANUAL - REV 001C