Connecting cables
5.2.

Connection with AUMA plug/socket connector

5.2.1.

Terminal compartment: open

SQR 14.2
For device insulation, appropriate (voltage-proof) cables must be used. Specify
cables for the highest occurring rated voltage.
Use connecting cable with appropriate minimum rated temperature.
For connecting cables exposed to UV radiation (outdoor installation), use UV
resistant cables.
Cross sections AUMA plug/socket connector:
Power terminals (U1, V1, W1, U2, V2, W2): max. 6 mm² flexible/10 mm² solid
PE connection
: max. 6 mm² flexible/10 mm² solid
Control contacts (1 to 50): max. 2.5 mm²
Figure 11: Connection AUMA plug/socket connector, version S
[1]
Cover
[2]
Screws for cover
[3]
O-ring
[4]
Screws for socket carrier
[5]
Socket carrier
[6]
Cable entry
[7]
Blanking plugs
[8]
Cable gland (not included in delivery)
Hazardous voltage!
Risk of electric shock.
Disconnect device from the mains before opening.
1.
Loosen screws [2] and remove cover [1].
2.
Loosen screws [4] and remove socket carrier [5] from cover [1].