Memory
Memory - - - - Storing Spectrum
Memory
Storing Spectrum- - - - Pictures
Storing Spectrum
Storing Spectrum
All spectrum-pictures may be stored in the COMBOLOOK
This is useful for documentation and use in the future for recognition; or identification of
a specific signal, through characteristic spectrum display.
The Mix-function helps in identifying and “finding the way back” to already known (and
previously stored) satellites.
The function places a previously saved spectrum on top of the current spectrum.
When the “right” satellite is found it will be like “fitting a hand to a glove”
To store measured
To store measured
To store measured
To store measured- - - - data:
* Choose the spectrum to store (i.e. exactly as displayed on the monitor) and push
button # 9 in the Main Menu (Memory).
* Select ”Save” button # 2.
* The instrument asks: -”SAVE. ARE YOU SURE ?”
* Check that the memory position (Mem Pos) is the right one (shown in lower-right of the
monitor).
If not, choose another one with the main-knob (Pos free: 00-99).
* Having selected a position, press button # 1 (YES).
* Notice that the setup of 13V/18V, 22 kHz on/off will be stored as well.
Text-editor:
When the spectrum is saved, the Text-editor appears on the monitor making it
possible to enter a name for that memory-position (ex. ASTRA 1D).
Use the knob to select the first letter (ex. A) and save it with the control-button. Move
to the next letter (ex. S) and so on.
To correct an entry; simply push button # 1 (Delete) and the cursor will index one
position backward.
To colle
To collect a stored spectrum
ct a stored spectrum:
To colle
To colle
ct a stored spectrum
ct a stored spectrum
* Select ”Memory”-function with button # 9 in the Main Menu.
* Select the spectrum you wish to load (use the main-knob: pos 00-99 displayed down
to the right in the monitor).
* Load the spectrum to the monitor with button # 1.
Notice that the function Reference cursor,
spectrum is loaded.
To mix a stored spectrum with an ongoing measurement:
To mix a stored spectrum with an ongoing measurement
To mix a stored spectrum with an ongoing measurement
To mix a stored spectrum with an ongoing measurement
* Select ”Memory”-function with button # 9 in the Main Menu.
* Select the spectrum you wish to load (use the main-knob: pos 00-99 displayed down
to the right in the monitor).
* Mix the spectrum with the ongoing measurement using button # 4.
- Turn off the Mix-memory by pushing the # 4 button again.
data:
data:
data:
Reference cursor, Ref mrkr, is enabled when a stored
Reference cursor,
Reference cursor,
Pictures.
Pictures
Pictures
Color
COMBOLOOK
COMBOLOOK
COMBOLOOK
19

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the COMBOLOOK Color and is the answer not in the manual?

Questions and answers

Table of Contents