INFORMATION REGARDING THE INSTALLATION OF THE INDOOR UNIT

INSTALLING THE REAR PANEL
1. Always mount the rear panel horizontally. Due
to the water tray within the indoor unit we
would advise that the outlet of the water tray
should be fractionally lower when installing as
this will aid drainage of the condensate
collected.
2. Fix the rear panel on the wall with screws.
3. Be sure that the rear panel has been fixed
firmly enough to withstand the weight of an
adult (60Kg), furthermore the weight should be
evenly shared by each screw.
The piping can be lead out on the right, left or directly behind the indoor unit as seen in fig. 1.
Please cut off the pipe hole guards if you are changing the pipe position. The unit also features
alternative guards for more pipe positioning.
Make sure that the drain pipe is underneath the pipelines. (Fig.3) (When the drain pipe passes
the room interior, some condensed water might occur to its surfaces if the humidity is very high).
Tidy up the copper pipes, electrical cables and water drains and pass them through the wall hole
drilled earlier (fig.2).
Hang the mounting slots of the indoor unit on the wall mounting bracket making sure is tight in
place (fig.3) so that the hooks at the bottom of the indoor unit match the hooks of the wall
mounting bracket (fig.4)
INSTALLATION GUIDE
INSTALLING THE PIPING HOLE
1. Make the piping hole (65mm diameter) in the wall at
a slight downward slant to the outdoor side (To aid
drainage of the condensate).
2. Insert the piping-hole sleeve into the hole to prevent
65mm
the connecting piping and wiring from been damaged
when passing through the hole.