ElectrIQ P12C-V2 User Manual

ElectrIQ P12C-V2 User Manual

12,000 btu portable air conditioner

Advertisement

USER MANUAL
12,000 BTU PORTABLE AIR CONDITIONER
P12C-V2
Thank you for choosing electriQ
Please read this user manual before using this innovative Air Conditioner and
keep it safe for future reference.
Visit our page www.electriQ.co.uk for our entire range of Intelligent Electricals

Advertisement

Table of Contents
loading

Summary of Contents for ElectrIQ P12C-V2

  • Page 1 12,000 BTU PORTABLE AIR CONDITIONER P12C-V2 Thank you for choosing electriQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference. Visit our page www.electriQ.co.uk for our entire range of Intelligent Electricals...
  • Page 2: Table Of Contents

    CONTENTS SAFETY INSTRUCTIONS FEATURES DIAGRAM AND ACCESSORIES INSTALLATION OPERATION REMOTE CONTROL WATER-DRAINAGE MAINTENANCE TROUBLESHOOTING TECHNICAL DATA SUPPORT Page 2 of 15...
  • Page 3: Safety Instructions

    SAFETY INSTRUCTIONS Important!  Carefully read the instructions before operating the unit  This appliance is for indoor use only.  Rating: This unit must be only connected to a 220-240 V / 50 Hz earthed outlet.  Installation must be in accordance with regulations of the country where the unit is used.
  • Page 4  Never use the mains plug or an external timer as a switch to start and stop the air conditioning unit. Use the provided ON/OFF button located on the control panel.  Always place the unit on a dry and stable surface. ...
  • Page 5: Features

    FEATURES FEATURES  Self-evaporative system - no external water tank needed  Powerful but compact  Hidden display on front of the unit  Enhanced design with hot air outlet positioned higher – this allows for improved performance with the use of a short hose ...
  • Page 6: Diagram And Accessories

    DIAGRAM Control Panel Handle TOP VIEW Air Inlet Display Panel Upper drainage port Air Inlet FRONT VIEW BACK VIEW RIGHT VIEW LEFT VIEW Power cable ACCESSORIES Lower Drainage port Exhaust hose Fishtail adaptor Slide bar Remote control Exhaust hose connector FRONT VIEW FRONT VIEW Page 6 of 15...
  • Page 7: Installation

    INSTALLATION Warning:Before using this unit, please keep it upright for at least 3-4 hours. This unit can easily be moved from one room to another. While moving the unit please note that it must always be kept upright and then placed on an even surface.
  • Page 8 INSTALLATION OF WINDOW KIT 1. Partially open the window and then fix the slide bare into the opening in the window, by putting it into position before closing the window onto it to seal the gap. 2. Push the fishtail adaptor into the slot in the slide bar Note: The slide bar is only designed to be installed with sliding or sash windows or doors.
  • Page 9: Operation

    OPERATION AND SETTINGS CONTROL PANEL & FUNCTION POWER BUTTON Press to turn unit “ON” or “OFF” MODE BUTTON Pressing this button will select between the COOL, DRY (dehumidify) and FAN modes. The lights next to the button indicate the currently running mode. COOL MODE: Cold air will be expelled through the front of the unit and hot air will be expelled through the vent hose.
  • Page 10 SLEEP MODE Press the Sleep button to enter sleep mode, the default fan speed is low and the Sleep mode indicator led will illuminate. When the sleep mode is turned on: After one hour the set temperature will increase by 1 degree Celsius, after another hour the set temperature will increase by another degree, and will then remain set at that temperature.
  • Page 11: Remote Control

    REMOTE CONTROL The air conditioner can be controlled with the remote control. Two AAA-batteries are required to use the remote control. Note: the air flow direction cannot be adjusted with the remote control. POWER : Press the POWER button to turn the machine on or off.
  • Page 12: Maintenance

    MAINTENANCE CLEANING Please shut off the unit and unplug from the mains before cleaning or performing any maintenance CLEAN THE SURFACE Clean the plastic housing with a duster or a soft wet cloth. Do not use chemical solvents (such as benzene, alcohol or gasoline) as they may cause irreversible damage.
  • Page 13: Troubleshooting

    TROUBLESHOOTING Do not repair or disassemble the unit by yourself, unauthorized repair attempts will invalidate the warranty and may cause bodily harm. Trouble Reason Solution No power supply Power-on and turn on the unit. Water-full indicator illuminated Drain the internal water tank The unit does Timer function is active Cancel Timer function...
  • Page 14: Technical Data

    Please contact the local council for details of your local household waste recycling centres. TECHNICAL DATA P12C-V2 Capacity 12,000 BTU Rated Input 1345W Running Current 6.0A...
  • Page 15: Support

    UK SUPPORT www.electriQ.co.uk/support Please, for your own convenience, make these simple checks before calling the service line. If the unit still fails to operate contact us using the form on our website or call: 0871 620 1057 1. Has the unit been standing upright for at least 2 hours? 2.