7.3 Type tests and environmental conditions

Phenomena
ESD
RF field AM
modulated
Fast transient
Surge
RF conducted
Radiated emission
Conducted
emission
Power frequency
magnetic field
Dry heat
Cold
Damp heat
Temperature variation
Vibration
Shock
Table 21: Type tests and environmental conditions
Test
Description
EN 61000-4-2
Enclosure contact
Enclosure air
EN 61000-4-3
Enclosure
EN 61000-4-4
Signal ports
Power ports
Ethernet ports
EN 61000-4-5
Ethernet ports
Power ports
I/O ports
EN 61000-4-6
All ports
EN 55022
Enclosure
EN 55022
DC power ports
Ethernet ports
EN 61000-4-8
Enclosure
EN 60068-2-2
+75 C, 40 % rel. humidity
EN 60068-2-1
-40 C
EN 60068-2-78
95 % rel. humidity (+40 C)
EN 60068-2-14 Nb
-40 C / +70 C, 3 h / 3 h, 2 cycles, 3 K/min
EN
60068-2-64
Vibration
ed. 2
trum A.3 (rolling
stock)
EN
60068-2-27
half-sine, 50 g peak, 11 ms
ed. 2
34
SmartMotion ST352
Test levels
6 kV (crit. A)
8 kV (crit. A)
20 V/m (crit. A)
(80 – 2700 MHz)
3 V/m (crit. A)
(2700 – 6000 MHz)
2 kV (crit. A)
2 kV (crit. A)
2 kV (crit. A)
2 kV (crit. B), shielded cab.
0,5 kV (crit. B)
1 kV, L to L (crit. A)
2 kV, L to GND (crit. A)
10 V/m (crit. A)
(0,15 – 80 MHz)
Class B
Class B
Class B
160 A/m (crit. A)
spec-
Category 1 (3 axis, 8 hours
per axis)