Installer manual Fleck 3150 NXT/NXT2 - Programming
6.1.5.6
System size
Set the number of valves to be connected (2 to 4 valves) in the system.
Info
Only visible in multiple valve systems and only present on the master #1 valve.
Options:
• 2 valves in the system (default);
• 3 valves in the system;
• 4 valves in the system.
1. Adjust the system size with
2. Press
to validate the selection and advance to the next
parameter.
6.1.5.7
Regeneration type
Select the regeneration type.
Options:
• time clock delayed (default): regeneration will take place, at the programmed regeneration
time, after the set amount of days has been reached (available only for system type 4);
• volume delayed: regeneration is requested when the volume of treated water reaches the
reserve capacity and will take place, at the programmed regeneration time (available only for
system type 4 & 6);
• volume immediate: regeneration is requested when the capacity is fully depleted. The
regeneration starts immediately (available for all system types).
1. Set regeneration type with
2. Press
to validate the selection and advance to the next
parameter.
6.1.5.8
Valve type
Select which valve is being used with the NXT.
Options:
• 2750 (default);
• 2850;
• 2900/2910;
• 3150;
• 3900;
• stager-notch cam.
78 / 190
and
.
and
.
Ref. MKT-IM-010 / F - 16.01.2023