Info
This screen is displayed only for metered systems.
Based upon the system capacity, reserve and inlet water hardness, the controller
calculates the volume of water that the system can treat between 2 regenerations.
When hardness unit is programmed in mg/L as CaCO
in grams as CaCO
the system can treat before requiring regeneration.
When hardness unit is programmed in °FTH, °dH or °eH, the capacity must be
programmed in Lx (unit of hardness) and correspond to the total volume of water the
system could treat if the inlet water hardness was 1° in the corresponding unit before
requiring regeneration.
1. Set the capacity with
2. Can be adjusted from 0 to 9.999.999;
3. Press
to validate the selection and advance to the next
parameter.
6.2.5.17 Hardness
Set the inlet water hardness in the unit set on chapter Hardness units [
Info
This screen is displayed only for metered systems
1. Set hardness with
ð Can be adjusted from:
ð 1 – 1999 mg/l;
ð 1- 199.9 °F;
ð 1 - 112.0 °dH;
ð 1 - 140.2 °eH.
ð Any value programmed above the maximum value for
each unit will be discarded and considered as the
maximum above mentioned value for the relevant unit.
2. Press
to validate the selection and advance to the next
parameter.
6.2.5.18 Reserve
Set the reserve type.
Info
Available only for softening metered delayed systems.
Ref. MKT-IM-010 / F - 16.01.2023
equivalent and correspond to the total equivalent mass of CaCO
3
,
and ;
,
and ;
Installer manual Fleck 3150 NXT/NXT2 - Programming
, the capacity must be programmed
3
Example: 1446 g of CaCO
capacity.
Page 110]
that
3
of
3
111 / 190