1. Adjust the time of regeneration with
2. Can be adjusted from: 00:00 to 23:59HR;
3. Press
to validate the selection and advance to the next
parameter.
6.2.5.24 Lock window
Set Lock Window: Enable lock windows then select the desired Lock Start time and Lock End time.
Info
Lock Window prevents the unit from regenerating during a specified time frame.
Two lock windows are available (Lock Window #1 and Lock Window #2).
Mandatory
Before deactivating lock window #1, you must deactivate lock window #2 first,
otherwise lock window #2 will remain active but not visible anymore in the
programming.
Lock window #1
Set Lock Window #1.
Options:
• off (default);
• on, start time and end time.
1. Enable lock window with
2. Press
to validate the selection and advance to the next
parameter.
3. Set lock start time with
4. Press
to validate the selection and advance to the next
parameter.
5. Set lock end time with
6. Press
to validate the selection and advance to the next
parameter.
Lock window #2
Set Lock Window #2.
Options:
• Off (default);
• on, start time and end time.
Ref. MKT-IM-010 / F - 16.01.2023
and
and
;
and
;
and
;
Installer manual Fleck 3150 NXT/NXT2 - Programming
;
Lock window #1 activated.
Lock window #1starts at
12:00.
Lock window #1ends at
13:00.