Ac+Dc Intensity Measurement; True Inrush ® Measurement - AEMC 205 User Manual

Power clamp-on meter
Table of Contents

Advertisement

4.2.6

AC+DC Intensity Measurement

Measurement
(2)
Range
Specified
Measurement
Range
(2)
Accuracy
(zero corrected)
Resolution
Note (1)
In DC, the display indicates "+OL" above +1800A and "+-OL" above
-1800A in REL mode. The "-" and "+" signs are managed (polarity).
In AC and AC+DC, the display indicates "+OL" above 1500A in PEAK
mode. The "-" and "+" signs are not managed.
- Bandwidth in AC = 3kHz
Note (2) In AC, any value between zero and the min. threshold of the
measurement range (0.15A) is forced to show "----" on the display.
Specific Specifications in MAX/MIN mode
(from 10Hz to 1kHz, and from 0.30A in AC):
Accuracy: add ± (1% R) to the values in the tables above.
PEAK capture time: 1ms min. to 1.5ms max.
Specific characteristics in PEAK mode in current
(from 10Hz to 1kHz in AC and AC+DC):
Accuracy: add ± (1.5% R +0.5A) to the values in the tables above.
PEAK capture time: 1ms min. to 1.5ms max.
4.2.7
True Inrush
Measurement Range
Specified Measurement Range
Accuracy
Resolution
Specific Specifications in PEAK mode in True InRush
Accuracy: add ± (1.5% R +0.5A) to the values in the table above.
PEAK capture time: 1ms min. to 1.5ms max.
0.15 to
59.99A
0 to 100% of the measurement range
± (1% R+10cts)
0.01A
®
Measurement
60.0 to
599.9A
± (1% R +3cts)
0.1A
6 to 600A
AC
0 to 100% of the measurement range
± (5% R +5cts)
38
AC: 600A
DC or PEAK:
600 to 900A
1A
6 to 900A
1A
®
(from 10Hz to 1kHz):
(1)
DC

Advertisement

Table of Contents
loading

Table of Contents