Installation (Cont.)
Installation of the outdoor unit
• The outdoor unit should be installed on a solid wall, or on the ground, and
fastened securely.
• Before connecting pipes and cables, decide on the best position on the
wall, leaving enough space for easy maintenance.
• Fasten the support to the wall using screw anchors that are particularly
suited to the type of wall.
• Use the largest size wall anchors that will suit the size and weight of the
unit, keeping in mind that the mounting will need to support the weight and
vibration of the unit for many years to come, without loosening.
• The unit must be installed following all relevant local regulations.
Water drainage from the outdoor unit
Condensed water and ice formed in the outdoor unit while in heating mode
can be drained away through a drain
pipe.
• Fasten the drain port in the 25mm
hole placed in the part of the unit, as
illustrated (Fig. 15).
• Connect the drain port and the drain
pipe.
• Make sure that water is drained into a
suitable place.
Electrical connections
• Take off the cover.
• Connect the cable wires to the
terminal board using the same
numbering as in the indoor unit.
• For the electrical connections, see
the wiring diagram on the back of the
cover (Fig. 16).
• Fasten the cables with a cable clamp.
• An efficient earth connection must be
ensured.
• Replace the cover.
1300 886 649 (AUS) 0800 836 761 (NZ) |
After Sales Support
Fig. 15
Drain port
Drain pipe
info@tempo.org