Installation

Installation of the indoor unit
• Before starting installation, decide on the position of the indoor and outdoor
units, taking into account the minimum space required around the units.
• Install the indoor unit in the room to be air conditioned, avoid installation in
corridors or communal areas.
Installing the mounting plate
• Use a spirit level to put the
mounting plate in a perfectly level
position vertically and horizontally.
• Drill 32mm deep holes in the wall
to fix the plate. Use a drill bit to fit
the 6mm plugs supplied.
• Insert the plastic anchors into the
hole.
• Fix the mounting plate by using the
provided tapping screws (Fig. 7).
• Check that the mounting plate is
correctly fixed.
Drilling a hole in the wall for the piping
• Decide where to drill the hole in the wall for the
piping, if necessary, according to the position of
the mounting plate.
• Install a flexible flange through the hole in the
wall to keep the latter intact and clean.
NOTE: The hole must slope downwards
towards the exterior (Fig. 8).
Keep the drain pipe down towards the direction
of the wall hole, otherwise leakage may occur.