Selecting the Installation Place

These instructions for installation of the Reverse Cycle Inverter Air
Conditioner are for use by an appropriately qualified, licensed installer. The
appliance must be installed in accordance with national wiring regulations.
Do not try to install the Air Conditioner on your own; doing so will
expose you to danger and void the warranty.
Indoor unit
• This Inverter Split System Air Conditioner is suitable for cooling or heating a
room of max. 15 square metres in size.
• Install the indoor unit level on a strong wall that is not subject to vibrations.
• The inlet and outlet ports should not be obstructed, the air should be able
to blow all over the room.
• Do not install the unit near a source of heat, steam or flammable gas.
• Install the unit near an electric socket or private circuit.
• Do not install the unit
where it will be exposed
to direct sunlight.
• Do not install the unit in
a laundry room.
• Install the unit where
connection between
indoor and outdoor unit
is as easy as possible.
• Install the unit where
it is easy to drain any
condensation water.
• Observe the minimum
clearances around the
unit as stated (Fig. 4).
• Check the machine
operation regularly and
leave the necessary
spaces, as shown in
Fig. 4.
• Install the indoor unit
where the filter is easily
accessible.
1300 886 649 (AUS) 0800 836 761 (NZ) |
PROTECT YOUR WARRANTY
Fig. 4
Mounting plate
Minimum clearances, in mm
After Sales Support
Condensed water drain pipe
Sleeve
Insulating covering
Electrical cable
Water drain pipe