ETC Echo Relay Panel Feedthrough Installation Manual
ETC Echo Relay Panel Feedthrough Installation Manual

ETC Echo Relay Panel Feedthrough Installation Manual

Hide thumbs Also See for Echo Relay Panel Feedthrough:

Advertisement

Quick Links

Echo Relay Panel Feedthrough
Installation Manual
Part Number: 7123M2102 Rev: F
Released: 2023-04

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Echo Relay Panel Feedthrough and is the answer not in the manual?

Questions and answers

Summary of Contents for ETC Echo Relay Panel Feedthrough

  • Page 1 Echo Relay Panel Feedthrough Installation Manual Part Number: 7123M2102 Rev: F Released: 2023-04...
  • Page 2 To view a list of ETC trademarks and patents, go to etcconnect.com/ip. All other trademarks, both marked and not marked, are the property of their respective owners. For a complete list of all third-party licenses that are fully incorporated herein to the extent required by each third-party license terms and conditions, please visit etcconnect.com/licenses.
  • Page 3: Table Of Contents

    Table of Contents Introduction Using this Manual Document Conventions Product Variants Relay Kits Option Cards and Accessories Help from ETC Technical Services Prepare for Installation Installation Environment Control Processor Power Requirements Panel Dimensions Clearance Relay Specification Verify the Contents of the Shipping Carton...
  • Page 4 Connect Control Wiring DMX Control Wiring and Termination Terminate the Network Connection Connect Panic Input/Panic Output Final Installation and Power Up Verify Installation Final Installation Power Up and Test 0–10V Option Card Overview Installation Connect Wiring DALI Option Card Overview Installation Install the ERP-FT-DALI Option Card Connect Wiring...
  • Page 5: Introduction

    Introduction Congratulations on your purchase of the Echo Relay Panel Feedthrough (ERP-FT). The ERP-FT panel offers high value power control with a small footprint, low heat dissipation, and low noise, allowing it to be installed in a variety of locations. Features of the ERP-FT panel include: sACN, DMX-512, or stand-alone control •...
  • Page 6: Using This Manual

    Using this Manual This manual contains procedures for field installation of the Echo Relay Panel Feedthrough, and additional relays. ® When viewing this document in electronic form (pdf file) with Adobe Acrobat Reader, blue text is a link within the document. If you click on the link, Acrobat will navigate to that section or topic or open an external client for internet browsing or email.
  • Page 7: Product Variants

    Product Variants This manual contains the procedures for installation of the Echo Relay Panel Feedthrough (ERP-FT). The panel is available with and without relays installed. ERP24-FT-24 ERP48-FT48 Standard models include: Model Description ERP24-FT Echo Relay Panel Feedthrough 24-way panel without relays...
  • Page 8: Option Cards And Accessories

    * two rack-mount kits are required for the 48- way relay panel Tamper-proof hardware ERP-FT-TPH Note: Any Echo Relay Panel Feedthrough enclosure, 24- or 48-position, supports up to two low-voltage control cards (ERP-FT-LVD, ERP-FT-DALI, or ERP-FT-CI) in the following combinations: ERP24-FT Option Card Combinations ERP48-FT Option Card Combinations...
  • Page 9 0-10V Dimming Control The 0-10V Dimming Control option card (ERP-FT-LVD) provides 24 outputs for control of 4-wire current-sink, 0-10 VDC or electronic loads. Each of the 24 outputs are rated to control a maximum of • 400 mA per channel (up to 50 ballasts per channel). Loss of power at the ERP-FT panel controller results in •...
  • Page 10 Contact Input The Contact Input card (ERP-FT-CI) provides the ability to directly control the relays using a momentary or maintained dry contact input. Contact Input Option Card on For more information, see page 35 Ride-Thru Option The Ride Thru Option (ERP-FT-RTO) maintains power to the ERP- FT panel controller for a minimum of 15 seconds in the event of a brown-out or power loss.
  • Page 11: Help From Etc Technical Services

    Help from ETC Technical Services If you are having difficulties and your problem is not addressed by this document, try the ETC support website at support.etcconnect.com or the main ETC website at etcconnect.com. If none of these resources are sufficient, contact ETC Technical Services directly at one of the offices identified below.
  • Page 12: Prepare For Installation

    Dry room (10%–90% humidity, non-condensing), 0°C–40°C (32°F–104°F) ambient • temperature, dust free. Echo Relay Panel Feedthrough 24 is intended to be wall mounted (surface only) or installed • in a standard 19 in (EIA) equipment rack utilizing the 19 in rack mount kit (ERP-FT-RMK).
  • Page 13: Panel Dimensions

    Panel Dimensions Models Height Width Depth ERP24-FT 666 mm (26.24 in) 435 mm (17.14 in) 157 mm (6.2 in) ERP48-FT 1,195 mm (47.06 in) 435 mm (17.14 in) 157 mm (6.2 in) Clearance ERP24-FT suggested mounting 1,219 mm (48 in) height to bottom of the panel. • ERP48-FT suggested mounting 610 mm (24 in) height to bottom of the panel. •...
  • Page 14: Relay Specification

    Relay Specification The Echo Relay Panel Feedthrough (ERP-FT) ships standard with either 12, 24, or 48 relays Relay Kits on page 3 installed and fully pre-wired for low-voltage control. Reference available models. Single Pole HID Relay UL Listed General Use 20 A @ 347 VAC General Use 20 A @ 347 VAC...
  • Page 15: Verify The Contents Of The Shipping Carton

    Verify the Contents of the Shipping Carton Standard Echo Relay Panel Feedthrough (ERP-FT) units ship complete and fully pre-wired with low-voltage relay control. As you remove the panel from the shipping carton, confirm the following items are included: ERP-FT with covers and locking doors attached with keys •...
  • Page 16: Cable Specification For Data And Control

    (14–10 AWG) copper wire DMX In and Belden 9729 or equivalent (contact DMX is RS485 serial and must be installed in series (i.e. Pass-Thru ETC for a list of daisy-chain) topology (J4 and J5) equivalents) Ethernet Belden 1583A (RJ45 (Category 5e or Install per EIA/TIA 568B.
  • Page 17: Cable Routing And Conduit Access

    Cable Routing and Conduit Access Echo Relay Panel Feedthrough has removable plates located on top, bottom and both sides to accommodate conduit fittings for line, load, and feed wiring. Two knockouts, one on each side of the user interface, are specifically provided for low-voltage (control) wiring.
  • Page 18: Installation Procedure

    Chapter 2 Installation Procedure Install Mounting Hardware 441 mm 1. Remove the front (17.35 in) covers with locking doors to reveal the panel interior. 394 mm 2. Align the panel to the (15.5 in) desired mounting location and mark all keyhole locations.
  • Page 19: Rough-In Conduit And Cable

    Rough-in Conduit and Cable The Echo Relay Panel Feedthrough has removable plates located on top, bottom and both sides to accommodate conduit fittings for line, load, and control electronics power wiring. Remove the plates to punch conduit access as required.
  • Page 20 WARNING: RISK OF DEATH BY ELECTRIC SHOCK! Failure to disconnect all power to the panel before working inside could result in serious injury or death. AVERTISSEMENT : RISQUE D'ELECTROCUTION! Travailler à l’intérieur du panneau sans avoir déconnecté le courant peut entrainer des blessures graves, voire mortelles.
  • Page 21 A Voltage Barrier may be used to separate multiple voltages and/or emergency circuits from normal circuits within the Relay Panel. This is an accessory option, sold separately, and available for use when local code requires. Contact ETC for assistance. 3. Repeat this process for the remaining Line and Load wires for the installation.
  • Page 22: Connect Power Control Electronics Ac Input

    Connect Power Control Electronics AC Input WARNING: RISK OF ELECTRIC SHOCK! Power must be off when you perform this procedure. AVERTISSEMENT : RISQUE DE DÉCHARGE ÉLECTRIQUE! L'alimentation doit étre éteinte avant d'exécuter cette procédure. Control electronics input power connects in the ERP-FT on screw terminals. The transformer is a multi-tap transformer with winding for 120 VAC and 240/277 VAC at 50/60 Hz.
  • Page 23: Connect Power Pigtail For Erp48-Ft

    Connect Power Pigtail for ERP48-FT In a standard model 48-way Echo Relay Panel Feedthrough, a spiral wrapped power pigtail cable is hard wired to the transformer in the top panel and connected to the transformer in the lower panel. This connection is made at the factory prior to shipment.
  • Page 24: Install Option Cards

    Install Option Cards Each option card is packaged separately. Review the graphic below for option card placement. Ride Thru Option Card DALI Option Contact Input Card or 0-10V Option Card Option Card Primary/Secondary Switch (ERP48-FT Only) Primary Secondary When using a combination of two option cards in an Echo Relay position position Panel, you will need to position the Primary/Secondary switch...
  • Page 25 Example 2: Two Card Configuration (Same Card Type) If you are using two option cards of the same type (e.g. two 0–10V option cards), the following configuration is required: Primary/Secondary Option Card 1 Option Card 2 Switch Position 0-10V (positions 1–24) 0-10V (positions 25–48) Secondary Example 3: Two Card Configurations (Different Card Types) If you are using two options cards of different types (e.g.
  • Page 26: Connect Control Wiring

    Connect Control Wiring Reference Cable Specification for Data and Control on page 12 for a complete listing of control wire specification. The following images show the connections to the low-voltage termination board. Ethernet connects directly to the back of the Power Control Processor Mk2. WARNING: RISK OF DEATH OR INJURY BY ELECTRIC SHOCK! 0–10V wiring may not be fully isolated from high-voltage AC power.
  • Page 27: Dmx Control Wiring And Termination

    The RDM position is not used. Terminate the Network Connection The Power Control Processor Mk2 in the Echo Relay Panel Feedthrough has an integrated network interface and ships with a 1 ft Cat5 patch cable and a network termination kit containing a two-part surface-mount connector.
  • Page 28 See the following illustration. Connect the Patch Cable The Echo Relay Panel Feedthrough ships with a 1 ft patch cable (N4036). Connect the patch cable from the surface-mount connector to the back of the user interface.
  • Page 29: Connect Panic Input/Panic Output

    Connect Panic Input/Panic Output The Echo Relay Panel Feedthrough offers a panic capability that complies with the UL 924 standard. When the ERP Feedthrough is properly connected and has a panic "look" stored, it will automatically play the recorded look when it receives a signal over the panic contact...
  • Page 30: Final Installation And Power Up

    Reference the Power Control Processor Mk2 Configuration Manual for configuration and system test information. If you have any difficulties installing your system, please contact ETC Technical Services at the office nearest you. ETC contact information is located in Help from ETC Technical Services on page 7...
  • Page 31: 0-10V Option Card

    Appendix A 0–10V Option Card Overview The 0–10V Dimming Control option card (ERP-FT-LVD) is designed for LED drivers and fluorescent ballasts. It sinks up to 400 mA current on each of its 24 outputs. Each channel output is linked one-to-one with a relay circuit for power control and can control up to 50 ballasts.
  • Page 32 Images in this section show a 24-channel panel (ERP24-FT). 1. Turn off power to the relay panel. 2. Remove the four screws securing the front panel to the ERP-FT. 3. Fold down the User Interface panel, taking care to leave all wire harnesses connected. This panel has two tabs that, when inserted, provide additional support for the fold-down panel.
  • Page 33: Connect Wiring

    Connect Wiring The 0–10V Dimming Control option card provides four bus connections for termination of six 0–10 V outputs each (24 channels). A pluggable screw-terminal connector is provided for each bus, and is labeled for ease of identification of each output. The removable connectors accept 0.25–4 mm (24–12 AWG) wire.
  • Page 34 Connect the Wire Harness 1. Connect one end of the provided wire harness to the Both connectors five-pin connector on the option card. The harness end oriented with should be oriented with the wires coming out of the wires coming out of the back back.
  • Page 35: Dali Option Card

    The DALI ballast is powered by an external DALI loop power supply which is supplied by • others. This supply is internally connected to the Echo Relay Panel Feedthrough. The number of power supplies needed for each DALI loop, is based on the connected load.
  • Page 36: Install The Erp-Ft-Dali Option Card

    Install the ERP-FT-DALI Option Card Images in this section show a 24-channel panel (ERP24-FT). 1. Turn off power to the relay panel. 2. Remove the four screws securing the front panel to the ERP-FT. 3. Fold down the User Interface panel, taking care to leave all wire harnesses connected.
  • Page 37: Connect Wiring

    Connect Wiring Note: Control wiring must be routed in separate conduit from the line voltage wiring for DALI ballasts. Note: The associated output loop terminal number should always match the relay circuit number inside the relay panel. For example: If relay 1 is connected to a DALI ballast load, control wiring would terminate to the ERP-FT-DALI option board output terminals labeled “+ 1 -”.
  • Page 38 Connect the Wire Harness 1. Connect one end of the provided wire harness to the Both connectors five-pin connector on the option card. The harness end oriented with should be oriented with the wires coming out of the wires coming out of the back back.
  • Page 39: Contact Input Option Card

    Appendix C Contact Input Option Card Overview The Contact Input Option Card (ERP-FT-CI) provides the ability to directly control the relays of the Echo Relay Panel using a momentary or maintained dry contact input. Installation WARNING: RISK OF DEATH BY ELECTRIC SHOCK! Failure to disconnect all power to the panel before working inside could result in serious injury or death.
  • Page 40: Connect Wiring

    Images in this section show a 24-channel panel (ERP24-FT). 1. Turn off power to the relay panel. 2. Remove the four screws securing the front panel to the ERP-FT. 3. Fold down the User Interface panel, taking care to leave all wire harnesses connected. This panel has two tabs that, when inserted, provide additional support for the fold-down panel.
  • Page 41: Programming

    7. Reattach the Contact Input pluggable screw header to the board and repeat the process for any additional contact inputs. Connect the Wire Harness 1. Connect one end of the provided wire harness to the Both connectors five-pin connector on the option card. The harness end oriented with should be oriented with the wires coming out of the wires coming...
  • Page 42 On Open determines the action that occurs when the contact is opened. The following • options are available: None (default): No action will be taken when the contact opens. Off : Off will be activated in the selected Space when the contact opens. Preset : The selected Preset will be activated in the selected Space when the contact opens.
  • Page 43: Compliance

    For current and complete compliance information, view the product datasheets at etcconnect.com. For complete product documentation, including compliance documentation, visit etcconnect.com/products. FCC Compliance Echo Relay Panel Feedthrough (For any FCC matters): Electronic Theatre Controls, Inc. 3031 Pleasant View Road Middleton, WI 53562 +1 (608) 831-4116 etcconnect.com...
  • Page 44 | Support support.etcconnect.com | Contact etcconnect.com/contactETC © 2023 Electronic Theatre Controls, Inc. | Trademark and patent info: etcconnect.com/ip Product information and specifications subject to change. ETC intends this document to be provided in its entirety. 7123M2102 Rev F Released 2023-04...

This manual is also suitable for:

Erp24-ftErp24-ft121pErp24-ft241pErp48-ftErp48-ft481pErp48-ft482p ... Show all

Table of Contents