7. Reattach the Contact Input pluggable screw header to the board and repeat the process for
any additional contact inputs.
Connect the Wire Harness
1. Connect one end of the provided wire harness to the
five-pin connector on the option card. The harness end
should be oriented with the wires coming out of the
back.
2. Connect the opposite end of the wire harness to the
connector on the termination board, to the left of the
Primary/Secondary switch. The harness end should be
oriented with the wires coming out of the back.
3. Set the Primary/Secondary switch as necessary. See
Primary/Secondary Switch (ERP48-FT Only)
4. Fold the User Interface panel up into place, taking care not to pinch any wires or cables.
5. Secure the panel using the four screws previously removed.

Programming

The ERP-FT is programmable through the Echo Relay Panel user interface. This setting
determines how each relay responds to a dry contact input signal.
1. When in the Main Menu, select Arch Setup.
2. Within the Arch Setup menu, select Contact Inputs.
When the Contact Input card is installed, you will have the following options within the
Contact Inputs menu:
Contact displays the number of contact being configured, 1–24.
Space determines the space in which the selected action will happen.
Contact Input Option Card
.
Both connectors
oriented with
wires coming
out of the back
37