Installation Partially Into Fireplace Cavity - Valor L1 1500KN Installation Manual

Direct vent zero clearance gas fireplace
Table of Contents

Advertisement

Venting

Installation Partially Into Fireplace Cavity

Note: Co-linear portion of vent system may only be
installed within a solid-fuel burning fi replace and
chimney.
The appliance can be adapted to co-linear applications
using an existing chimney. The appliance must not be
connected to a chimney fl ue serving a separate solid-
fuel burning appliance.
Requires the Valor Co-Axial to Co-Linear appliance
Adapter 1156CLA, 46DVA-GCL or equivalent, two
lengths of 2-ply 3" diameter fl exible chimney liner
approved for venting gas appliances, a co-linear
termination kit, and fl ashing or a co-linear to co-axial
adapter and either a high wind vertical vent terminal
cap or a low profi le vertical termination.
The appliance must be fully enclosed while maintaining
clearances to combustibles detailed elsewhere in this
manual.
Rules for Co-Linear Venting
• Maximum 40 feet vertical pipe
• Minimum 10 feet vertical
• Maximum off set 8 feet with liners at minimum
45 degrees from horizontal plane
• Restrictor: Not required when using co-linear venting.
Note: Co-linear fl exible aluminum venting should be
professionally inspected periodically for corrosion
and damage and replaced when necessary. If the
installation does not allow for future inspection or
replacement of the fl exible aluminum venting, then
stainless steel vent liners should be used.
Co-Linear Conversion
2 x 3"
liners
Co-linear
adapter
3" min.
bend radius
Framed
wall
Clearances to combustible
materials listed elsewhere
in this manual apply
Engine
Co-Linear installation partially into existing fi replace
Approved co-linear
termination or approved
co-linear adapter
and approved
Flashing
co-axial
termination
2 x 3"
liners
1156
Co-linear
adapter
27

Advertisement

Table of Contents
loading

This manual is also suitable for:

L1 1500kp

Table of Contents