1.
Do not place Propane/LP supply tank(s) inside any structure. Propane/LP supply tank(s) must be placed outdoors.
2.
Do not use this firebox as a wood-burning fireplace. Use only decorative unvented room heaters (log set).
3.
Keep all air openings in front and bottom of fireplace clear and free of debris. This will ensure enough air for proper
combustion.
4.
Do not run fireplace:
l
Where flammable liquids or vapors are used or stored.
l
Under dusty conditions.
5.
Before using furniture polish, wax, carpet cleaner, or similar products, turn fireplace off. If heated, the vapors from
these products may create a white powder residue within burner box or on adjacent walls or furniture.
6.
Do not use firebox if it has been under water due to shock hazard that could result with the blower accessory (if
installed) in place.
7.
Turn firebox off and let cool before servicing. Only a qualified service person should service and repair firebox.
8.
Operating firebox above elevations of 4,500 feet could cause pilot outage.
9.
To prevent performance problems, do not use propane/LP fuel tank of less than 100 lb. capacity.
10. This firebox should not be installed in a bedroom or bathroom.
11. Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using these added items can
cause sooting. Do not add lava rock around base. Rock and debris could fall into the control area of fireplace. After
servicing, always replace screen before operating fireplace.
12. Use only provided hood.
QUALIFIED INSTALLING AGENCY
Only a qualified agency should perform installation and replacement of gas piping, gas utilization equipment or
accessories, and repair and servicing of equipment. The term "qualified agency" means any individual, firm,
corporation, or company that either in person or through a representative is engaged in and is responsible for:
a)
Installing, testing, or replacing gas piping or
b)
Connecting, installing, testing, repairing, or servicing equipment; that is experienced in such work; that is familiar
with all precautions required; and that has complied with all the requirement of the authority having jurisdiction.
PRODUCT FEATURES
OPERATION
This firebox is designed for use with approved ANSI Z21.11.2 decorative type unvented room fireplaces. (Physical
size limitations apply. Refer to minimum firebox requirements supplied with log fireplace.) It requires no outside
venting or chimney making installation easy and inexpensive. When used without the blower, the firebox requires no
electricity making it ideal for emergency backup heat.

LOCAL CODES

Install and use fireplace with care. Follow all codes. In the absence of local codes, use the latest edition of The
National Fuel Gas Code, ANSI Z223.1, also known as NFPA 54*.
*Available from:
American National Standards Institute, lnc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, lnc.
1 Batterymarch Park
Quincy, MA 02269-9101