7-TYPE OF FASTENING

HOW TO FASTEN THE INSERT
It is obligatory to anchor the product to a surface during annual maintenance operations by the authorised technician, or when the fuel
is loaded, the combustion chamber may be extracted from its seat with the aid of two retractable guides.
The product can be anchored to an existing surface (which must have certain characteristics) or it can be fastened to the optional support.
Attention! the support surface of the insert must be completely flat.
Fastening to an existing surface - suggested characteristics
Installation data
The surface where the fixed part of the insert is to be fastened must be in R250 kg/cm2 concrete, if the supporting surface is made of poor
material that might not hold it, it is advisable to use a slab suitable for fastening.
We recommend using an anchor bolt with the following characteristics:
DIMENSIONS (TYPE)
SX 10
TYPE
Lt (anchor bolt length)
SX 10
50 mm
Technical Dept. - All rights reserved - Reproduction prohibited
DIAMETER
10 mm
Screw Ø V
P (Minimum hole depth)
x Lv
8x60 mm
70 mm
LENGTH
50 mm
KEY
Lv= Lt+S (Screw length)
Lt= Anchor bolt length
S= Maximum thickness of object to be fastened
Øf = drill bit diameter
P=Minimum hole depth
Øv = screw diameter
Øf (drill bit diameter) S (Max object thickness)
10 mm
10 mm