Technical data
11.5.3
DTT35 design, dimensions of the process connections
MB
S /
W
AF 22
G½"
 23
Process connection versions
All dimensions in mm (in).
L = insertion length L
Item No.
Process connection versions DTT35
DB
Clamp 1" to 1½" (ISO 2852) or DN 25 to 40(DIN
32676)
DL
Clamp 2" (ISO 2852) or DN 50 (DIN 32676)
HL
APV-Inline, DN50, PN40, 316L, B = bores 6 x
⌀8.6 mm (0.34 in) + 2 x thread M8
LB
Varivent F DN25-32, PN 40, 316L
LL
Varivent N DN40-162, PN 40, 316L
MR
Metal sealing system for hygienic processes, G½"
thread, thread length
L1 = 14 mm (0.55 in). Suitable welding boss
available as an accessory. 316L
PG
DIN 11851, DN25, PN40 (including coupling nut),
316L
40
DB
(CLAMP 1")
DL
43.5 (1.71)
50.5 (1.99)
LB(Varivent F)
LL
50 (1.97)
66 (2.6)
PL
(DIN 11851)
PG
51 (2.01)
27 (1.06)
68 (2.68)
44 (1.73)
Flowphant T DTT31, DTT35
(CLAMP 2")
56.5 (2.22)
64 (2.52)
(Varivent N)
HL
B
68 (2.68)
84 (3.31)
(DIN 11851)
PH
Hygiene standard
3-A marked and EHEDG-certified (only with
self-centering seal, as per EHEDG position
paper)
3-A marked and EHEDG-certified
3-A marked and EHEDG-certified
3-A marked and EHEDG-certified
3-A marked and EHEDG-certified (only with
self-centering sealing ring, as per EHEDG
position paper)
(APV-Inline)
61.5 (2.42)
82 (3.23)
100 (3.94)
(DIN 11851)
39 (1.54)
56 (2.21)
A0011776