Replacement Of The Thermocouple; Replacement Of Pilot Injector; Replacement Of Edb Unit - Infinity 880 BF Owner's Manual

Room sealed inset live fuel effect gas fire
Table of Contents

Advertisement

Infinity 880 BF Maintenance Instructions
SECTION TWELVE Maintenance Instructions Continued

Replacement of the Thermocouple

1. Remove the Thermocouple from the rear of the Valve.
2. Disconnect the Thermocouple wires from the E.D.B.
3. Undo the Thermocouple nut from the pilot assembly and remove Thermocouple and replace.
4. Replace in reverse order, turn on gas supply, check for soundness, correct operation and re-
commission.
Replacement of the Pilot Injector
1. Repeat operations 1-9 for removal of gas control.
2. Undo the pilot tube nut at the pilot bracket.
3. Pull the pipe gently back taking care not to damage pipe or olive hook nut.
4. Remove the pilot injector from inside the pilot bracket.
5. Clean or replace pilot injector
Replacement of the EDB Unit
1. Remove the M3 nuts holding the Heat Shield, remove the M3 nut and remove the E.D.B.
2. Pull the E.D.B. forward and remove all the wires & connections
3. Replace E.D.B. and reconnect all the wires
4. Re-assemble in the reverse order.
Turn on the gas supply, check for gas soundness, operation and re-commission appliance.
When ordering parts quote 'INFINITY 880 BF' and the serial number of the fire, which can be found
on the data badge on bottom left hand side of fire. (Refer to cleaning instructions for trim removal.)
Infinity Fires
Telford
Shropshire
TF3 3AR
Telephone 01952 200 444
Web Site
www.infinityfires.co.uk
21
LT 6456 (Iss 2 046/14)

Advertisement