Thermal Performance

TM
The Color Force II
12, 48 & 72 fixtures feature internal fans that control the internal cooling.
If the internal temperature of the Color Force II™ exceeds 75ºC the output of the fixture will be
reduced for automatic protection. This happens on rare and extreme conditions when ambient
temperature is over 35ºC or the internal fans are blocked or damaged.
The airflow to and from the fan must not be constricted to maintain the maximum light output of the
TM
Color Force II
.

Troubleshooting

Troubleshooting is a process of elimination. First, rule out the other field factors (i.e. bad
connections, faulty cables and power supplies). For technical support and/or parts, please contact
your selling dealer or the offices listed in this manual.
Symptom
Fixture does not
respond to DMX
control.
Noise from fixture unit.
Low LED output.

Maintenance

With care, the Color Force II™ will require little maintenance. However, as the unit is likely to be used in
a stage environment, we recommend periodical internal inspection and cleaning of any resulting dust
and/or cracked oil residue.
Do not spray liquids on the front or rear panel. If the front enclosure requires cleaning, wipe with a mild
detergent on a damp cloth.
Color Force II™ User Manual V2.1
Possible Cause
Set to wrong or different DMX address.
Bad cable connecting DMX control and
fixture.
Bad in/through connection
between adjacent fixtures.
Console patch is incorrect.
Fan malfunction.
Internal temperature is over
the limit. Fan is not working.
www.chroma-q.com
Solution
Check DMX address
and Mode settings.
Check/replace DMX run
from the console.
Check DMX values in the
Setup/DMX Data screen
as described above to
verify the fixture is
"seeing" the DMX data.
Check fan.
Verify Engine temperature
using the Setup/Eng
Temp screen as
described above.
Check "Fan Control"
mode. Check fan.
Check for airflow - to and
from the internal fan.
Check area ventilation.