5-Reset
To reset the fixture to the factory default settings,
1.
From the Main Menu, press Up Up Up Up or Down
2.
Press Enter
3.
Press and hold Enter
Menu.
All control menu commands are reset to factory defaults:
DMX address
Personality
No DMX Present
Look Store
PWM Frequency

2.6 DMX Protocol

DMX Personality:
Studio One 100
Studio
Studio
Studio
One 100 D D D D
One 100
One 100
1-Dimmer
V1.
V1.
V1.
V1.6 6 6 6
[1 ch]
Channel 1
All LED
Total
1 DMX channel

2.7 Thermal Performance

The internal cooling system of the Studio One fixture is by convection and built with automatic protection. The fixture's
automatic protection reduces the output when the internal temperature reaches the maximum limit due to extreme ambient
conditions.
3. Troubleshooting
Troubleshooting is a process of elimination. First, rule out the other field factors (i.e. bad connections, faulty cables and
power supplies). For technical support and/or parts, please contact your selling dealer or the offices listed in this manual.
Symptom
Fixture does not respond to DMX
control.
Low LED output.
Studio One 100 D User Manual
Enter, display shows reset?
Enter
Enter
Enter for 2 seconds, display shows Hold for 2 sec. and Done, then back to the Main
Enter
Enter
1
Dimmer
Hold Last
1
750Hz
Possible Cause
Set to wrong or different DMX address.
Bad cable connecting DMX control and
fixture.
Bad in/through connection between
adjacent fixtures.
Internal temperature is over the limit.
www.chroma-q.com
Down to access 5-Reset.
Down
Down
13
Solution
Check DMX address and Mode
settings.
Check/replace DMX run from the
console.
Check area ventilation.