Dmx Protocol - Studio Force V Phosphor; Thermal Performance; Troubleshooting - Chroma Studio Force V Phosphor User Manual

Hide thumbs Also See for Studio Force V Phosphor:
Table of Contents

Advertisement

2.6 DMX Protocol – Studio Force V Phosphor
Studio Force V Phosphor - DMX Personality
Studio Force V
Phosphor v1.06
Channel 1
Channel 2
Channel 3
Channel 4
Total

2.7 Thermal Performance

The Studio Force V Phosphor is built with an internal fan for internal cooling. The fixture output is automatically reduced
when internal temperature exceeds 75ºC for automatic protection. This happens on rare and extreme conditions when
ambient temperature is over 35ºC or the internal fans are blocked or damaged.
The airflow to and from the fan must not be constricted to maintain the maximum operating capacity of the Studio Force V
Phosphor fixtures.
3.

Troubleshooting

Check and eliminate the possible external field factors such as bad connections, faulty cables, damaged power supplies, bad
control, etc. The items in the table below are basic guidelines for quick troubleshooting. For technical support and/or parts,
please contact your selling dealer or the offices listed in this manual.
Symptom
Fixture does not respond to
DMX control.
Noise from fixture unit.
Low LED output.
Studio Force V Phosphor User Manual
KHL
[3ch]
Kelvin
Hue
Level
3 DMX channels
Possible Cause
Set to wrong or different DMX address.
Bad cable connecting DMX control and fixture.
Bad in/through connection between adjacent
fixtures.
Fan malfunction.
Internal temperature is over the limit.
Fan is not working.
www.chroma-q.com
RGWA
[4ch]
Red
Green
White
Amber
4 DMX channels
16
Look Sel
[1ch]
Look 1 – 32 (Playback)
1 DMX channel
Solution
Check DMX address and Mode
settings.
Check/replace DMX run from the
console.
Check/replace DMX runs between
fixtures.
Check fan.
Check "Fan Control" mode.
Check fan.
Check for airflow - to and from the
internal fan.
Check area ventilation.
V1.5 December 2014