Cable
from the
RFC)
Input
power
cable for
the
TMC11
H
(supplie
d with
power
from the
external
equipme
nt)
In the -48 V DC power supply scenario, the RFC can obtain the power only from the external equipment. The
TMC11H, however, can obtain power from the external power equipment or from the RFC. If the TMC11H
obtains power from the RFC, the total power consumption of the TMC11H cannot exceed 800 W.
Procedure
Step 1 Prepare the input power cables for the RFC and TMC11H.
1.
2.
Step 2 Link the OT terminal at one end of the input power cable for the RFC to the input wiring terminal
on the DCDU-01, tighten the screw, and then connect the other end to the external equipment,
as shown in
Issue 01 (2011-10-25)
NEG(-) wire
RTN(+) wire
NEG(-) wire
NOTE
Prepare the cable of proper length based on the actual cable route.
Add connectors to both ends of the input power cable for the RFC and power cable for the
TMC11H according to
Power Cable.
Figure
12-22.
NOTE
Before installing the power cables, remove the protecting hood from the DC input wiring terminal block
on the DCDU-01. After the cables are installed, reinstall the protecting hood.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
One End
OT terminal (2.5
2
mm
, M6)
OT terminal (4
2
mm
, M6)
OT terminal (4
2
mm
, M6)
Table
12-5. For details, see Assembling the OT Terminal and the
12 Installing the Cables
The Other End
Remarks
Blue
According to the
Black
external
equipment
According to the
Blue
external
equipment