Points to Note Before Servicing

• At servicing, be sure to turn OFF the power source according to the specified steps and disconnect the power plug.
• Be sure to disconnect the power plug on a regular basis and remove dust and dirt accumulated around the outlet with dry
cloth.
CAUTION:
Leaving the power plug connected for a long time in an environment having a lot of dust, moisture, or oily smoke will
cause a fire. (Because dust accumulated in the surrounding area will absorb moisture and cause an insulation failure)
• Be careful not to be injured by burrs of edges, sharp corners or protrusions.
CAUTION:
Hazardous area such as corners, edges, springs and other sharp sections may be remaining on products. Always be
aware of the presence of hazardous area to avoid injury caused by contacting and/or striking those area, by not over-
concentrating on service work.

Points to Note at Cleaning

When performing cleaning using organic solvent such as alcohol, be sure to check that the component of solvent is vaporized
completely before assembling.

Notes on Assembly/Disassembly

Follow the items below to assemble/disassemble the device.
1. Disconnect the power plug to avoid any potential dangers during assembling/disassembling works.
2. If not specially instructed, reverse the order of disassembly to reinstall.
3. Ensure to use the right screw type (length, diameter, etc.) at the right position when assembling.
4. To keep electric conduction, binding screws with washers are used to attach the grounding wire and the varistor. Ensure to
use the right screw type when assembling.
5. Unless it is specially needed, do not operate the device with some parts removed.
6. Never remove the paint-locked screws when disassembling.
CAUTION:
English
CAUTION
DOUBLE POLE/NEUTRAL FUSING
The fuse may be in the neutral, and that the mains shall be disconnected to de-energize the phase conductors.
German
VORSICHT
ZWEIPOLIGE BZW. NEUTRALLEITER-SICHERUNG
Die Sicherung kann sich im Nullleiter befinden und das Hauptnetz muss abgetrennt werden, um die Phasenleiter
stromlos zu machen.

Points to Note when Tightening a Screw

When a thin plates is used in some parts for the light weighting purpose, warn the following.
In the case of a screw hole with a triangle mark near it as shown in the figure below, strongly tightening the screw may damage
or deform the screw hole.
In the case of a screw hole with a triangle mark, take care not to apply too much force when tightening the screw.