Battery Test - Bosch Solution 6000-IP User Manual

Table of Contents

Advertisement

Solution 6000-IP
User Guide
To test zone Zn1
open then close
Zone 1 Name
Press OK or MENU
To test zone Zn2
open then close
Zone 1 Name
Press OK or MENU
3. Open and close each zone that needs to be tested.
A zone that has been successfully tested will no
longer scroll on the keypad display.
When all zones have been tested, the keypad will
display:
All zones have been
successfully tested
Press OK or MENU
4. Press [OK] to save and exit, or press [MENU] to exit
without saving.
System > System Testing >

Battery Test

This menu allows you to manually test the systems back
up battery. The system will automatically test the battery
every four hours and every time the system is armed.
The battery test can take up to two minutes to complete
and the keypad will display the voltage of the battery
during the test.
Enter programming mode (PIN + MENU) then,
1. Press [MENU] + [7] + [9] + [1].
The keypad will display current voltage whilst under
test:
Battery test in progress.
Please wait..
Voltage = 13.4V
To Go Back Press OK
If the battery has passed the test, the keypad will
display:
Battery Test Passed
Press OK To Continue
To Go Back Press OK
If the battery has failed the test, the keypad will
display:
38
2. Press [OK] to exit.
MENU 7-9-1
Battery Test Failed
Please Call For Service
To Go Back Press OK
Bosch Security Systems 10/22 BLCC615U