Dell PowerEdge HS5610 Installation And Service Manual page 39

Table of Contents

Advertisement

Table 41. 10 x 2.5-inch SAS4/SATA Configuration with iDRAC
Dell PowerEdge Server Standard
Operating Support (ASHRAE A2
compliant) All options supported
unless otherwise noted.
○ SM only support 6x2.5"SAS/
SATA drives at HDD#0~5, and
HDD Bracket GG6M3 x2 are
required at empty HDD bay.
● 100G PCIe and OCP3.0 NIC could
only support optic transceiver with
thermal Spec 85C and power
<=2.5W
● 25G PCIe NIC could not support
thermal spec 70C optic transceiver
with power higher than 1.2W ·
● 25G OCP3.0 NIC with 4 ports or
PCIe cooling tier higher 5 could
only support optic transceiver with
thermal spec 85C and power <=1.2W
● 25G OCP3.0 NIC with PCIe cooling
tier lower than or equal to 5 could
not support thermal spec 70C optic
transceiver with power higher than
1.2W
● With RM config only support max.
30C ambient when CPU Base
TDP>=205W
● The following SAS drives could NOT
support in RM. (But could support in
front SM)
○ Kioxia PM6 SAS all capacities
○ SATA SSD, Hynix SE5031 all
capacities or thermal spec <70C
Table 42. 8 x 2.5-inch NVMe configuration with iDRAC
Dell PowerEdge Server Standard
Operating Support (ASHRAE A2
compliant) All options supported
unless otherwise noted.
● HPR Gold (VHP) Fan is required for
all configurations
● STD HSK is required for CPU Base
TDP <=150W
● HPR HSK is required for CPU Base
TDP >150W
● 2-processor all configs or 1-processor
with RM config requires 7x fans
● 1-processor without RM config
requires 5x fans
● HW restriction is required for CPU
Base TDP >225W
○ SM only support 4x2.5"NVMe
at HDD#0~3, and HDD Bracket
GG6M3 x3 are required at empty
HDD bay.
● 100G PCIe and OCP3.0 NIC could
only support optic transceiver with
thermal spec 85C and power <=2.5W
Dell PowerEdge Server Extended
Inletient 40° C Operating Support
(ASHRAE A3 compliant)
● Not support OCP transfer rate >25G
or cooling tier > 10
● Optic Transceiver with spec 85C is
required
● Two PSUs are required. System
performance may be reduced in the
event of a PSU failure
Dell PowerEdge Server Extended
Inletient 40° C Operating Support
(ASHRAE A3 compliant)
● Not support CPU Base TDP > 150W
● HPR Gold (VHP) Fan is required.
● STD HSK is required
● Not support BOSS M.2 Module
● Not support Non-Dell qualified
peripheral cards and Channel devices
(FW) cards
● Not support NIC consuming power
>= 25W.
● Not Support Config with RM
● Not support OCP transfer rate >25G
or cooling tier > 10
● Optic Transceiver with spec 85C is
required
● Two PSUs are required. System
performance may be reduced in the
event of a PSU failure
Dell PowerEdge Server Extended
Inletient 45° C Operating Support
(ASHRAE A4 compliant)
Dell PowerEdge Server Extended
Inletient 45° C Operating Support
(ASHRAE A4 compliant)
● Not support