➢ Operation mode
OFF – Selecting this option disables the floor heating mode, i.e. neither
are active.
Floor Protection – This function is used to keep the floor temperature below the set maximum temperature
to protect the system from overheating. When the temperature rises to the set maximum temperature,
the reheating of the zone will be switched off.
Comfort mode – This function is used to maintain a comfortable floor temperature, i.e. the controller will
monitor the current temperature. When the temperature rises to the set maximum temperature, the zone
heating will be switched off to protect the system from overheating. When the floor temperature drops
below the set minimum temperature, the zone reheat will be switched back on.
➢ Min. temperature
The function is used to set the minimum temperature to protect the floor from cooling down. When the
floor temperature drops below the set minimum temperature, the zone reheat will be switched back on.
This function is only available when
➢ Max. temperature
The maximum floor temperature is the floor temperature threshold above which the controller will switch
off the heating regardless of the current room temperature. This function protects the installation from
overheating.

4.2. ADDITIONAL CONTACTS

Menu
The function allows you to utilize additional contact devices. It is first necessary to register such a contact (1-6 pcs.). To do
this, select the
Registration
After registering and switching on the device, the following functions will appear:
➢ Information - information about the status, operating mode and contact range is displayed on the controller screen
➢ ON - option to enable/disable contact operation
➢ Operation mode – user available option to activate the selected contact operation mode
➢ Time mode – the function allows setting the contact operation time for a specific time
The user can change the contact status by selecting/deselecting the
mode
➢ Constant mode – the function allows setting the contact to operate permanently. It is possible to change the contact
status by selecting/deselecting the
➢ Relays – the contact works according to the zones to which it has been assigned
➢ Drying – if the
Maximum Humidity
➢ Schedule settings – the function allows setting a separate contact operation schedule (regardless of the status of
the controller zones).
CAUTION
The
Drying
function works only in the
➢ Remove – this option is used to delete the selected contact.
Comfort Mode
Fitter's Menu
option and briefly press the communication button on the device, e.g. MW-1.
Active
option
is exceeded in a zone, this option allows start-up of the air dehumidifier
Cooling
is selected.
Active
option,
operation mode.
23
Floor Protection
nor
Comfort Mode
Additional contacts
and to set
the
Duration