APPENDIX D - TROUBLESHOOTING FLOW CHARTS

SCENARIO 1: TURN THE KEY TO THE ON POSITION AND NO POWER
Remove the
battery pack.
24VDC or battery voltage?
Remove the
floor basket.
Remove the two screws that
fasten the rear floor mat to
the front frame.
Disconnect the power
harness (5c and 5d) from
the controller.
0VDC?
Check power harness
for continuity.
Replace as necessary.
0VDC?
Replace the
controller.
29
Measure voltage across terminals 1 and
3 on connector 4a on the battery pack.
See figure 9 on page 8.
More than 16VDC?
Try to recharge the batteries.
Load test and replace if
necessary.
Reinstall the
battery pack.
Measure voltage
across 5c and 5d.
Insert the multimeter probes into the
terminal with the red wire (pin 7) and
the terminal with the black wire (pin 13)
on the back of the main harness
connector 7a. See figure 11.
0VDC? – Check main
circuit breaker (1) and
battery harness for
continuity (4a
terminals 1 to 4c and
4a terminals 3 to 4d).
24VDC or battery voltage?
Reconnect the power
harness to the controller.
24VDC or battery voltage?
LiteRider_SG_REVA_040711
0VDC?
Open the control
panel. Disconnect the
main harness from
the control panel
harness.