Run Screens (continued)
Tank Volume
CAT TANK=0000.0 GAL
RES TANK=0000.0 GAL
NXT
CAT
RES
Press CAT or RES
(Press NXT to go to Alarm screen)
CAT TANK PRESET
IS 0000.0
NEW VALUE? XXXX.X
QUIT
RESET
or
RES TANK PRESET
IS 0000.0
NEW VALUE? XXXX.X
QUIT
RESET
Press QUIT
Alarm
NO ALARMS
NXT
Press NXT
Current Recipe
ACTIVE RECIPE IS 00
NEW VALUE? XX
NXT
Press unmarked key to get back to the Main Title
screen.
Press SETUP key to access the Setup
screens.
12
684-015
Pendant Screens
RPT
RPT
RPT
This screen can be used to display how much fluid is left in
the catalyst feed tank (CAT TANK) and the resin feed tank
(RES TANK). By pressing the CAT or RES key you will see
a screen that looks like the one of the two following screens.
Enter a value that is less than the amount of fluid that is in
the tank and press the ENTER key. The screen should now
display the new value on line 2. If you want to use the same
value that was previously displayed, press the RESET key.
Press the QUIT key to go back to the previous TANK
VOLUME screen. As fluid is used from the tank, the value
for the catalyst and resin tank will drop. When one or both
of them reaches 0, the unit will stop and the alarm will
display.
If an alarm is activated on the Precision Mix™, this screen
automatically appears, displaying the alarm that occurred.
See the alarm descriptions on pages 24and 25 This screen
holds the last three alarms.
appear on the bottom of the screen. NOTE: A Run Report
will clear the Alarm screen.
This screen only appears when the recipe portion of the
program is turned on. This screen will show you the recipe
the unit is currently running.
The most recent alarm will