Inventory Keys A - F: The default setting allows the user to quickly dispense coins
•
from the A - F tubes by pressing the corresponding MMI button. This section allows
you to disable that function.
•
Settings: Save the current settings or restore the original settings.
Display Contrast: Adjust the contrast of the MMI display. Press Up to increase
•
contrast and Down to decrease contrast.
Idle Screen Amount: Set the information displayed on the idle screen. Select
•
between:
o Inventory – Displays the full amount of money in the cassette, including the
safe coins. Safe coins are the minimum number of coins that need to be in the
tubes to continue normal operation.
o Payable – Displays the total amount of money in the cassette, minus the safe
coins.
o Cashbox – Displays the amount routed to the cashbox.
o Nothing – No information displayed.
Error Log
Select View to scroll through a list of recent errors and select Reset to erase the error log.
Test
Auto Self-Tests: Runs an automated test of all motor functions and displays pass/fail
•
results.
Manual Self-Tests: Allows you to test specific functions of the coin changer. Scroll to
•
select the test, and then click
Gates: Test the coin changer's routing mechanisms by selecting All Gates or choose
•
a specific gate to test. Opening the MMI will not interrupt the test and will allow you to
view the performance of the gate as it operates.
Info: Quickly review information about the coin changer, including current cassette
•
information and firmware versions.
Language
Scroll to select your preferred language.
Gryphon
™
to perform the test.
START
© 2021 Crane Payment Innovations.
All rights reserved.
Coin Changer User Guide