7 Diagnostics and servicing
22
7. Open the tensile ring on the old electronics module and pull out
the old electronics module.
8. Compare the new electronics module with the old one. The type
label of the electronics module must correspond to that of the old
electronics module.
9. Insert the new electronics module.
10. Screw in and tighten the two screws with a Torx screwdriver.
11. Lead the connection cable through the cable gland.
12. Insert the wire ends into the open terminals according to the wir-
ing plan and tighten them.
13. Check the hold of the wires in the terminals by lightly pulling on
them.
14. Tighten cable gland and check on tightness. The seal ring must
completely encircle the cable.
15. Carry out a fresh adjustment. See chapter " Set up, new adjust-
ment".
16. Screw the housing lid back on
The electronics exchange is now finished.
7.4

How to proceed if a repair is necessary

You can find an instrument return form as well as detailed information
about the procedure in the download area of our homepage. By doing
this you help us carry out the repair quickly and without having to call
back for needed information.
Proceed as follows in case of repair:
Print and fill out one form per instrument
Clean the instrument and pack it damage-proof
Attach the completed form and, if need be, also a safety data
sheet outside on the packaging
Ask the agency serving you to get the address for the return ship-
ment. You can find the agency on our homepage.