Vega VEGACAP 27 Operating Instructions Manual page 27

Capacitive rod electrode for level detection relay (dpdt)
Hide thumbs Also See for VEGACAP 27:
Table of Contents

Advertisement

Ʋ Cable gland
Ʋ Blind plug
Ʋ Closing cap
Screw terminals
Adjustment elements
Mode switch
Ʋ A
Ʋ B
Potentiometer
Voltage supply
Operating voltage
Power consumption
Electrical protective measures
Protection rating
Altitude above sea level
Overvoltage category
Ʋ up to 2000 m (6562 ft)
Ʋ up to 5000 m (16404 ft)
Protection class
Approvals
Instruments with approvals can have different technical specifications depending on the version.
For that reason the associated approval documents of these instruments have to be carefully
noted. They are part of the delivery or can be downloaded by entering the serial number of your
instrument into the search field under www.vega.com as well as in the general download area.
VEGACAP 27 • Relay (DPDT)
M20 x 1.5, ½ NPT
M20 x 1.5, ½ NPT
½ NPT
for wire cross-section up to 1.5 mm² (AWG 16)
Min. detection or dry run protection
Max. detection or overflow protection
Switching point adaptation
20 ... 253 V AC, 50/60 Hz, 20 ... 72 V DC (at
U >60 V DC, the ambient temperature can be max.
50 °C/122 °F)
1 ... 9 VA (AC), approximately 1.5 W (DC)
IP66/IP67 (NEMA Type 4X)
up to 5000 m (16404 ft)
III
II
I
9 Supplement
27