AX Seri es-St andard I nst ruct i ons Manual

3.1 DFB_Capture

Supported Products
AX-308E, AX-364E, AX-324N, AX-332E
DFB_Capture captures the commanded pulses of the specified high-speed counter according to the designated external trigger
device.
FB/FC
Instruction
FB
DFB_Capture
Input
Name
Designate the source
Counter
of the specified high-
speed counter.
Execute the
instruction when
bEnable
bEnable changes to
Define the mask range
uiMaskValue
of Capture.
Define the minimum
diDeltaMin
difference between
each Capture
Define the maximum
diDeltaMax
difference between
each Capture
Define the rising edge
bEdgeSelect
*3
or falling edge capture
Graphic Expression
Function
Data Type
COUNTER_REF
BOOL
True.
.
*2
*2
.
BOOL
Setting Value
(Default value)
DFB_
DFB_COUNTER_REF
*1
(Cannot be null.)
True/False
(False)
UINT
Positive number or 0(0)
Positive number,
DINT
negative number or 0(0)
Positive number,
DINT
negative number or 0(0)
True/False
(False)
Chapt er 3
ST Language
DFB_Capture_instance(
Capture :=,
Counter :=,
bEnable :=,
uiMaskValue :=,
diDeltaMin :=,
diDeltaMax :=,
bEdgeSelect :=,
bCycle :=,bValid =>,
bBusy =>,
bError =>,
ErrorID =>,
bCapFlag =>,
diCapValue =>,
diCapValuePrevious =>,
diDelta =>,
bCapLenBeyondFlag =>,
dwCapLenBeyondCount =>);
Timing for Updating
-
-
When bEnable shifts to True, the
setting parameters of
uiMaskValue will be updated.
When bEnable shifts to True and
Busy is False
When bEnable shifts to True and
Busy is False
When b Eable is rising edge,
update the parameter of
bEdgeSelect
2 4