AX Seri es-St andard I nst ruct i ons Manual

4.4 DFB_GetAllECATSlaveInfo

Supported Products
AX-308E, AX-364E
DFB_GetAllECATSlaveInfo gets all the slaves' information.
FB/FC
Instruction
FB
DFB_GetAllECATSlaveInfo
Input
Name
bExecute
Output
Name
bDone
bBusy
bError
ErrorID
DFB_GetAllECATSlaveInfo (
Function
Execute the
instruction when
bExecute changes to
True.
Function
The execution of FB is
completed.
True when the
instruction is enabled.
True if an error occurs.
Indicates the error code
Graphic Expression
ST Language
bExecute :=,
bDone =>,
bBusy =>,
bError =>,
ErrorID =>,
slaveInfoArray =>,
uSlaves =>,);
Data Type
(Default value)
BOOL
Data Type
BOOL
BOOL
BOOL
DFB_ECAT_Diag_ERROR*
Setting Value
Timing for Updating
True/False
(False)
Output Range
(Default value)
True/False(False)
True/False(False)
True/False(False)
1
DFB_ECAT_Diag_ERROR
Chapt er 4
-