4.9 Error Codes and Troubleshooting

The following table lists the error codes corresponding to the FBs and the contents of the errors:
Description
DFB_ECAT_Diag_MASTER_CANT_BE_FOUND
DFB_ECAT_Diag_MASTER_ERROR
DFB_ECAT_Diag_SLAVE_
CANT_BE_FOUND
DFB_ECAT_Diag_MASTER_RESTART_TIMEOUT
DFB_ECAT_Diag_SLAVE_
RESTART_TIMEOUT
DFB_ECAT_Diag_MASTER_DISABLE
Cause of Error
EtherCAT master
please make sure the configuration of EtherCAT
cannot be found.
Diagnostics of
EtherCAT master
state is wrong.
EtherCAT slave
please make sure the EtherCAT master address is
cannot be found.
Time out occurs when
restart EtherCAT
master.
Time out occurs when
restart EtherCAT
slave.
EtherCAT master is
disabled.
Corrective Action
The EtherCAT master is not in the mapping,
master is correct.
Please troubleshoot the errors in EtherCAT
master before execute the FB.
The EtherCAT master is not in the mapping,
correct
Please check if the timeout is too short or the
internet has been lost.
Please check if the timeout is too short or the
internet has been lost.
Please check whether to enable the EtherCAT
master.