Dfb_Ecgetslavecount - Delta Standard AX Series Instruction Manual

Table of Contents

Advertisement

AX Seri es-St andard I nst ruct i ons Manual

4.2 DFB_EcGetSlaveCount

Supported Products
AX-308E, AX-364E
DFB_EcGetSlaveCount gets the number of slaves that are connected to the master.
FB/FC
Instruction
FB
DFB_EcGetSlaveCount
Input
Name
bExecute
Output
Name
bDone
bBusy
bError
ErrorID
uSlaves
DFB_EcGetSlaveCount (
Function
Execute the
instruction when
bExecute changes to
True.
Function
The execution of FB is
completed.
True when the instruction
is enabled.
True if an error occurs.
Indicates the error code if
an error occurs.
The number of slaves.
Graphic Expression
ST Language
bExecute :=,
bDone =>,
bBusy =>,
bError =>,
ErrorID =>,
uSlaves =>,
);
Setting Value
Data Type
(Default value)
True/False
BOOL
Data Type
BOOL
BOOL
BOOL
DFB_ECAT_Diag_ERROR*
UINT
Timing for Updating
(False)
Output Range
(Default value)
True/False(False)
True/False(False)
True/False(False)
DFB_ECAT_Diag_ERROR
(DFB_ECAT_Diag_NO_ERROR)
0~128(0)
Chapt er 4
-
6 7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Standard as02puStandard as04pu