Technical data Max. del. Max. del. Height Pipe con- Weight Power Noise pressure volume nection level bar / spec. Type weight 1 l/min H mm dBA / 50 Hz KC21 G ½ 0.22 KC31 G ½ 0.32 KC35 G ½ 0.22 KC45 G ½...
Signs on the pump It is imperative that signs affixed to the machine, ATTENTION e.g.: Pay attention of the max. tightening torque for • arrow indicating the direction of rotation piping connection • symbols indicating fluid connections Type Pipe Brass be observed and kept legible.
Electric wiring 6 Start up / Shut down Start up ATTENTION Switch off at the mains. All service work must be carried out by quali- After connection the electrical wires, close the fied service personnel. Pump must be discon- terminal box. Briefly start the motor (max. 30 sec.) nected from the power source and all rotating and check the rotation according to the arrow on parts must stand still.
9 Trouble shooter’s guide Fault Cause Remedy Motor does not start, no motor At least two of the power supply Check fuses, terminals and supply noise leads have failed leads . Overload has tripped Inspect overload Motor does not start, humming noise One of the supply leads has failed See above Impeller faulty...
10 Spare part 10.1 Spare part list for the miniature centrifugal pumps series KC2 ...KC45 Item Description Item Description Stator with terminal board 16 Hexagon head cap screw DIN 931 Pump body 17 Spring washer DIN 127 Thing annexed 18 Spring washer DIN 127 Canal cover 19 Woodruff key...
11 Repair Brinkmann miniature centrifugal pumps series KC21...KC45 11.1 Exchange the rotary shaft seals: 16)Reconnect pump to the electrical supply. Fill up 1) Disconnect the pump from the power supply. the pump! Check up the marks on the pump unit. 2) Loosen hexagon head cap screws (16).
Brinkmann miniature centrifugal pumps series KC21...KC45-UO12 (special make) 11.2 Exchange the rotary mechanical seal: 1) Disconnect the pump from the power supply. 11) Reconnect pump to the electrical supply. Fill Check up the marks on the pump unit. up the pump! 2) Loosen hexagon head cap screws (16).
13 EC declaration of conformity DEUTSCH / ENGLISH /FRANÇAIS / ESPAÑOL EG-Konformitätserklärung EC declaration of conformity / Déclaration de conformité CE / Declaração de conformidade CE Hersteller / Manufacturer / Constructeur / Fabricante Brinkmann Pumpen, K. H. Brinkmann GmbH & Co. KG Friedrichstraße 2, D-58791 Werdohl Produktbezeichnung / Product name / Désignation du produit / Designação do produto Kleinkreiselpumpen / Miniature Centrifugal Pumps / Petites pompes centrifuges / Bombas centrifugas...
Need help?
Do you have a question about the KC21 Series and is the answer not in the manual?
Questions and answers