BRINKMANN PUMPS KC60 Operating Instructions Manual

BRINKMANN PUMPS KC60 Operating Instructions Manual

Miniature centrifugal pumps series

Advertisement

Quick Links

BRINKMANN-Miniature Centrifugal Pumps Series
Brinkmann Pumpen
K. H. Brinkmann GmbH & Co. KG
Friedrichstraße 2
D-58791 Werdohl
Tel.: +49-2392 / 5006-0
Fax.: +49-2392 / 5006-180
Subject to change without prior notice.
© Brinkmann Pumpen
BE7100 Operating Instructions
(Translation of original)
12/2022
Edition
KC60
www.brinkmannpumps.de
sales@brinkmannpumps.de
Order - No. : BE7100 ENGLISH
1
11
Page
of

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KC60 and is the answer not in the manual?

Questions and answers

Summary of Contents for BRINKMANN PUMPS KC60

  • Page 1 BE7100 Operating Instructions (Translation of original) BRINKMANN-Miniature Centrifugal Pumps Series KC60 Brinkmann Pumpen K. H. Brinkmann GmbH & Co. KG Friedrichstraße 2 D-58791 Werdohl Tel.: +49-2392 / 5006-0 www.brinkmannpumps.de Fax.: +49-2392 / 5006-180 sales@brinkmannpumps.de Subject to change without prior notice.
  • Page 2: Table Of Contents

    Brinkmann-Miniature Centrifugal Pumps Series KC60 Contents 9 Trouble shooter’s guide ........6 Indication to the manual ........2 Description of product ........2-3 10 Spare part ............7 Safety instructions ..........3 11 Repair ............8-9 Transport and storage ........4 12 Disposal ............
  • Page 3: Safety Instructions

    Type weight 1 l/min H mm dBA / 50 Hz KC60 G ¾ 0.92 / 1.06 1) Dimensions in accordance with page 4 2) Noise emissions measured in accordance with DIN 45635 at a distance of 1 m The motor is surface-cooled and compliant with DIN IEC 34 and EN 60034 (protection degree IP 55).
  • Page 4: Transport And Storage

    Type Pipe Brass be observed and kept legible. connection Unauthorized alterations and production KC60 G ¾ 40 Nm of spare parts Any modification may be made to the machine only after consultation with the manufacturer. Using When installed the space around the pump...
  • Page 5: Start Up / Shut Down

    Electric wiring 6 Start up / Shut down Start up ATTENTION Switch off at the mains. All service work must be carried out by quali- After connection the electrical wires, close the fied service personnel. Pump must be discon- terminal box. Briefly start the motor (max. 30 sec.) nected from the power source and all rotating and check the rotation according to the arrow on parts must stand still.
  • Page 6: Trouble Shooter's Guide

    9 Trouble shooter’s guide Fault Cause Remedy Motor does not start, no motor At least two of the power supply Check fuses, terminals and supply noise leads have failed leads . Overload has tripped Inspect overload Motor does not start, humming noise One of the supply leads has failed See above Impeller faulty...
  • Page 7: Spare Part

    10 Spare part 10.1 Spare part list for the miniature centrifugal pumps series KC60 Item Description Item Description Stator with terminal board 16 Hexagon head cap screw DIN 931 End shield 17 Spring washer DIN 127 Thing annexed 18 Spring washer...
  • Page 8: Repair

    11 Repair Brinkmann miniature centrifugal pumps series KC60 11.1 Exchange the rotary shaft seal: 15)Reconnect pump to the electrical supply. Fill up 1) Disconnect the pump from the power supply. the pump! Check up the marks on the pump unit.
  • Page 9: Disposal

    Brinkmann miniature centrifugal pumps series KC60-UO12 (special make) 11.2 Exchange the rotary mechanical seal: 1) Disconnect the pump from the power supply. 11) Reconnect pump to the electrical supply. Fill Check up the marks on the pump unit. up the pump! 2) Loosen hexagon head cap screws (16).
  • Page 10: Eclarations Of Conformity

    Manufacturer Brinkmann Pumpen, K. H. Brinkmann GmbH & Co. KG Friedrichstraße 2 D-58791 Werdohl Germany This declaration of conformity is issued under the sole responsibility of Brinkmann Pumps and belongs to the following product. Product name Miniature Centrifugal Pumps Type...
  • Page 11 Produktbezeichnung / Product name / Désignation du produit / Designação do produto Kleinkreiselpumpen / Miniature Centrifugal Pumps / Petites pompes centrifuges / Bombas centrifugas Typ / Type / Tipo KC60 Das bezeichnete Produkt stimmt mit den folgenden Richtlinien des Rates zur Angleichung der Rechtsvorschriften der EG-Mitgliedsstaaten überein: The named product conforms to the following Council Directives on approximation of laws of the EEC Member States: Le produit sus-mentionné...