BRINKMANN PUMPS SBC1520 Operating Instructions Manual

BRINKMANN PUMPS SBC1520 Operating Instructions Manual

-horizontal end suction pumps

Advertisement

Quick Links

BE8085
BRINKMANN-Horizontal End Suction Pumps
SBC1520...1820
Brinkmann Pumpen
K. H. Brinkmann GmbH & Co. KG
Friedrichstraße 2
D-58791 Werdohl
Tel.: +49-2392 / 5006-0
Fax.: +49-2392 / 5006-180
Subject to change without prior notice.
© Brinkmann Pumpen
Operating Instructions
(Translation of original)
11/2019
Edition
www.brinkmannpumps.de
sales@brinkmannpumps.de
Order - No.: BE8085 ENGLISH
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SBC1520 and is the answer not in the manual?

Questions and answers

Summary of Contents for BRINKMANN PUMPS SBC1520

  • Page 1 BE8085 Operating Instructions (Translation of original) BRINKMANN-Horizontal End Suction Pumps SBC1520...1820 Brinkmann Pumpen K. H. Brinkmann GmbH & Co. KG Friedrichstraße 2 D-58791 Werdohl Tel.: +49-2392 / 5006-0 www.brinkmannpumps.de Fax.: +49-2392 / 5006-180 sales@brinkmannpumps.de Subject to change without prior notice.
  • Page 2: Table Of Contents

    BRINKMANN-Cutter pumps SBC1520…1820 Brinkmann–Horizontal End Suction Pumps Series SBC1520…1820 Contents 9 Trouble shooter’s guide ........9 Indication to the manual ........2 Description of product........2 10 Spare part ............10 Safety instructions ..........4 11 Repair Instructions / Replacing the rotary Transport and storage ........
  • Page 3 BRINKMANN-Cutter pumps SBC1520…1820 Limit of Application (Table 1) Type Mediums Coolants, cooling- and cutting-oils on WARNING request. ≥ 150 °C Flashing point of the Risk of fire and explosion! medium to be Pump may not be used in potentially explosive pumped environments.
  • Page 4: Safety Instructions

    BRINKMANN-Cutter pumps SBC1520…1820 3 Safety instructions Safety instructions relevant for operation When operating the pump, the safety instructions contained in this manual, the relevant national ac- – If hot or cold machine components involve cident prevention regulations and any other ser-...
  • Page 5: Transport And Storage

    BRINKMANN-Cutter pumps SBC1520…1820 – During any assembly or disassembly pro- Unauthorized alterations and pro- cess the pumps must be secured against duction of spare parts tipping trough ropes for example at all Any modification may be made to the machine times.
  • Page 6 BRINKMANN-Cutter pumps SBC1520…1820 Electric wiring WARNING Electric shock! All service work must be carried out by quali- fied service personnel. Pump must be discon- nected from the power source and all rotating parts must stand still. Reassure that pump is...
  • Page 7: Start Up / Shut Down

    BRINKMANN-Cutter pumps SBC1520…1820 7 Operation Wiring diagram e.g. Delta connection WARNING 3 x 400 V, 50 Hz Risk of injury by uncontrolled start-up of resp. 380-415 V, 50 Hz the pump or absence of emergency shutt of switch! Drawing 2...
  • Page 8: Servicing And Maintenance

    BRINKMANN-Cutter pumps SBC1520…1820 8 Servicing and Maintenance WARNING Risk of fire and explosion! CAUTION The creation of an ignition spark with the pres- Risk of burns! ence of an ignitable Aerosol can lead to risk of – The pump must have cooled down suffi- fire and explosion.
  • Page 9: Trouble Shooter's Guide

    BRINKMANN-Cutter pumps SBC1520…1820 9 Trouble shooter’s guide Fault Cause Remedy Motor does not start, no motor At least two of the power supply Check fuses, terminals and supply noise leads have failed leads. Overload has tripped Inspect overload Motor does not start, humming...
  • Page 10: Spare Part

    BRINKMANN-Cutter pumps SBC1520…1820 10 Spare part Spare part list for the Brinkmann 10.1 pumps Series SBC1520…1820 Drawing 4 Item Description Item Description Stator with terminal board Pump body Motor flange 51 Intake cover End shield 52 Connection cover Terminal box cover...
  • Page 11: Repair Instructions / Replacing The Rotary Mechanical Seal / The Shaft Clamp

    BRINKMANN-Cutter pumps SBC1520…1820 – Remove the woodruff key (53) from the insert Indications to the spare part or- 10.2 shaft (91). Loosen the socket head cap screws (65) and remove the bushing car- Spare parts are available from the supplier.
  • Page 12 BRINKMANN-Cutter pumps SBC1520…1820 Dismantling the insert shaft Assembling the insert shaft and 11.2 11.3 motor shaft WARNING Risk of jamming or crushing during pump installation or removal! 1 = Shaft clamp – Secure pump with appropriate hoist. 2 = Insert shaft...
  • Page 13: Disposal

    BRINKMANN-Cutter pumps SBC1520…1820 ATTENTION Assembly help and detailed instruction is de- manded for the assembly of the pump and adjusting of the cutting unit! – Request the required documents from the manufacturer. – Note torques for the screw connections! Tightening torques for screwed connections Thread - ...
  • Page 14: Ec Declaration Of Conformity

    Produktbezeichnung / Product name / Désignation du produit / Designación del producto Cutterpumpen / Horizontal End-Suction Pumps / Pompes Broyeuses / Bombas Trituradoras Typ / Type / Tipo SBC1520…1820 Das bezeichnete Produkt stimmt mit den folgenden Richtlinien des Rates zur Angleichung der Rechtsvorschriften der EG-Mitgliedsstaaten überein: The named product conforms to the following Council Directives on approximation of laws of the EEC Member States: Le produit sus-mentionné...

This manual is also suitable for:

Sbc1820

Table of Contents