Brinkmann Free Flow-Immersion Series SFT450…1100 Contents 9 Trouble shooter’s guide ........7 Indication to the manual ........2 Description of product ........2-3 10 Spare part ............8-9 Safety instructions ..........4 11 Repair ............... 9 Transport and storage ........4 12 Disposal ............
Page 3
Technical data Max. del. Max. del. Height Depth of Weight Power pressure volume immersion 50 / 60 Hz bar / spec. Type weight 1 l/min H mm h mm SFT450 / 300 2.6 / 2.94 / 430 / 550 / 800 /1050 1050 SFT710 / 300...
• Guards for moving parts (e.g. coupling) must not 3 Safety instructions be removed from the machine while in opera- When operating the pump, the safety instructions contained in this manual, the relevant national tion. accident prevention regulations and any other •...
Electric wiring 5 Installation and Connection Mechanical installation During any assembly or disassembly process the pumps must be secured against tipping trough ropes for example at all times. All service work must be carried out by quali- Pumps must be mounted securely. Piping, tank and fied service personnel.
6 Start up / Shut down ATTENTION Start up The SFT pump should be operated in continual ATTENTION operation mode, not pulsed mode! Pulsed mode causes increased wear due to the Switch off at the mains. return flow of chips and additional load on the After connection the electrical wires, close the bearings terminal box.
9 Trouble shooter’s guide Fault Cause Remedy Motor does not start, no motor At least two of the power supply Check fuses, terminals and supply noise leads have failed leads . Overload has tripped Inspect overload Motor does not start, humming noise One of the supply leads has failed See above Impeller faulty...
10 Spare part 10.1 Spare part list for the immersion pumps of the series SFT450…SFT1100 Item Description Stator with terminal board Motor flange End shield Terminal box up to 4.0 kW Terminal box frame 6.5 kW Terminal box cover 6.5 kW Fan cover Ball bearing DIN 625...
10.2 Indications to the spare part order 11.2 Assembling the insert shaft and motor shaft Spare parts are available from the supplier. Standard commercially available parts are to be ATTENTION purchased in accordance with the model type. The ordering of spare parts should contain the Clean the contact surfaces of the insert shaft (2) following details: (inside) and the motor shaft (3).
13 EC declaration of conformity DEUTSCH / ENGLISH /FRANÇAIS / ESPAÑOL EG-Konformitätserklärung EC declaration of conformity / Déclaration de conformité CE / Declaración de conformidad CE Hersteller / Manufacturer / Constructeur / Fabricante Brinkmann Pumpen, K. H. Brinkmann GmbH & Co. KG Friedrichstraße 2, D-58791 Werdohl Produktbezeichnung / Product name / Désignation du produit / Designación del producto Freistrom-Tauchpumpen / Free-flow Immersion Pumps / Pompes plongeantes non - engorgeables / Bombas de...
Need help?
Do you have a question about the SFT Series and is the answer not in the manual?
Questions and answers