Temperature of 0 ... 80 °C medium Particle-size in 27 mm STA2500 the medium 26 mm SAL2500 Safety sign according with 16mm SGL2200 ISO 3864 – B.3.6 28 mm SFL2350 Where non-compliance with the safety instructions may cause a risk to the machine and it’s function...
Page 3
50 / 60 Hz level Type spec. weight 1 l/min H mm h mm dBA / 50 Hz STA2500 / 330 2550 18.5 / 21.3 / 460 / 580 / 830 /1080 1080 SAL2500 / 340 2600 18.5 / 21.3...
• Guards for moving parts (e.g. coupling) must not 3 Safety instructions be removed from the machine while in opera- When operating the pump, the safety instructions contained in this manual, the relevant national tion. accident prevention regulations and any other •...
5 Installation and Connection Electric wiring Mechanical installation During any assembly or disassembly process the pumps must be secured against tipping trough ropes for example at all times. Pumps must be mounted securely. Piping, tank and All service work must be carried out by quali- pumps must be mounted without any tension.
6 Start up / Shut down ATTENTION Start up The SFL pump should be operated in continual ATTENTION operation mode, not pulsed mode! Pulsed mode causes increased wear due to the Switch off at the mains. return flow of chips and additional load on the After connection the electrical wires, close the bearings terminal box.
9 Trouble shooter’s guide Fault Cause Remedy Motor does not start, no motor At least two of the power supply Check fuses, terminals and supply noise leads have failed leads. Overload has tripped Inspect overload Motor does not start, humming noise One of the supply leads has failed See above Impeller faulty...
10 Spare part 10.1 Spare part list for the immersion pumps of the series STA/SAL2500, SGL2200, SFL2350 Item Description Motor Bearing housing Woodruff key DIN 6888 Bearing shaft Ball bearing DIN 628 Socket head cap screw DIN 912 Bearing cover Coupling 10 Nilos-ring 11 Threaded pin...
10.2 Indications to the spare part order 11.2 Assembling the insert shaft and motor shaft Spare parts are available from the supplier. Standard commercially available parts are to be ATTENTION purchased in accordance with the model type. The ordering of spare parts should contain the Clean the contact surfaces of the insert shaft (2) following details: (inside) and the motor shaft (3).
13 EC declaration of conformity DEUTSCH / ENGLISH /FRANÇAIS / ESPAÑOL EG-Konformitätserklärung EC declaration of conformity / Déclaration de conformité CE / Declaración de conformidad CE Hersteller / Manufacturer / Constructeur / Fabricante Brinkmann Pumpen, K. H. Brinkmann GmbH & Co. KG Friedrichstraße 2, D-58791 Werdohl Produktbezeichnung / Product name / Désignation du produit / Designación del producto Tauchpumpen / Immersion pumps / Pompes plongeantes / Bombas de inmersión...
Need help?
Do you have a question about the STA2500 and is the answer not in the manual?
Questions and answers