BRINKMANN PUMPS KTF151/140 Operating Instructions Manual

BRINKMANN PUMPS KTF151/140 Operating Instructions Manual

Immersion pumps

Advertisement

Quick Links

BE5500
BRINKMANN Immersion Pumps
Brinkmann Pumpen
K. H. Brinkmann GmbH & Co. KG
Friedrichstraße 2
D-58791 Werdohl
Tel.: +49-2392 / 5006-0
Fax.: +49-2392 / 5006-180
Subject to change without prior notice.
© Brinkmann Pumpen
Operating Instructions
(Translation of original)
09/2021
Edition
KTF151 ... 303
www.brinkmannpumps.de
sales@brinkmannpumps.de
Order - No. : BE5500 ENGLISH
1
9
Page
of

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KTF151/140 and is the answer not in the manual?

Questions and answers

Summary of Contents for BRINKMANN PUMPS KTF151/140

  • Page 1 BE5500 Operating Instructions (Translation of original) BRINKMANN Immersion Pumps KTF151 … 303 Brinkmann Pumpen K. H. Brinkmann GmbH & Co. KG Friedrichstraße 2 D-58791 Werdohl Tel.: +49-2392 / 5006-0 www.brinkmannpumps.de Fax.: +49-2392 / 5006-180 sales@brinkmannpumps.de Subject to change without prior notice. Order - No.
  • Page 2: Table Of Contents

    Brinkmann Immersions pumps of the series KTF151 ... 303 Contents Indication to the manual ........2 8 Servicing and Maintenance ....... 6 9 Trouble shooter’s guide ........7 Description of product ........2-3 Safety instructions ..........4 10 Spare part ............8 Transport and storage ........
  • Page 3 Technical data Number of Max. del. Max. del. Height Depth of Weight Power Noise stage pressure bar / volume immersion 50 / 60 Hz level Type spec. weight 1 l/min H mm h mm dBA / 50 Hz KTF151 / 140 0.63 / 0.725 KTF152 / 180...
  • Page 4: Safety Instructions

    Safety instructions relevant for operation 3 Safety instructions • If hot or cold machine components involve When operating the pump, the safety instructions contained in this manual, the relevant national hazards, they must be guarded against acci- accident prevention regulations and any other dental contact.
  • Page 5: Installation And Connection

    Electric wiring 5 Installation and Connection Mechanical installation During any assembly or disassembly process the pumps must be secured against tipping trough ropes for example at all times. All service work must be carried out by quali- Pumps must be mounted securely. Piping, tank and fied service personnel.
  • Page 6: Start Up / Shut Down

    6 Start up / Shut down 8 Servicing and Maintenance Start up ATTENTION ATTENTION The surface of the motor must be kept free of dirt. Switch off at the mains. The motor shaft is spinning in permanently greased After connection the electrical wires, close the ball bearings (with special grease and increased terminal box.
  • Page 7: Trouble Shooter's Guide

    9 Trouble shooter’s guide Fault Cause Remedy Motor does not start, no motor At least two of the power supply Check fuses, terminals and supply noise leads have failed leads. Overload has tripped Inspect overload Motor does not start. humming noise One of the supply leads has failed See above Impeller faulty...
  • Page 8: Spare Part

    10 Spare part 10.1 Spare part list for the immersion pumps of the series KTF151 ... 303 Item Description Stator with terminal board Motor flange End shield Terminal box Fan cover Ball bearing DIN 625 10 Ball bearing DIN 625 11 Gasket 12 Stud bolt with bond up to 1.1 kW 13 Retaining ring up to 1.1 kW...
  • Page 9: Ec Declaration Of Conformity

    12 EC declaration of conformity DEUTSCH / ENGLISH /FRANÇAIS / ESPAÑOL EG-Konformitätserklärung EC declaration of conformity / Déclaration de conformité CE / Declaración de conformidad CE Hersteller / Manufacturer / Constructeur / Fabricante Brinkmann Pumpen, K. H. Brinkmann GmbH & Co. KG Friedrichstraße 2, D-58791 Werdohl Produktbezeichnung / Product name / Désignation du produit / Designación del producto Tauchpumpen / Immersion pumps / Pompes plongeantes / Bombas de inmersión...

Table of Contents