BRINKMANN PUMPS SBA141 Series Operating Instructions Manual

BRINKMANN PUMPS SBA141 Series Operating Instructions Manual

Vertical end suction pumps

Advertisement

Quick Links

BE8144-V
BRINKMANN-Vertical End Suction Pumps
SBA141...143-V and SBF125-V
Brinkmann Pumpen
K. H. Brinkmann GmbH & Co. KG
Friedrichstraße 2
D-58791 Werdohl
Tel.: +49-2392 / 5006-0
Fax.: +49-2392 / 5006-180
Subject to change without prior notice.
© Brinkmann Pumpen
Operating Instructions
(Translation of original)
10/2021
Edition
www.brinkmannpumps.de
sales@brinkmannpumps.de
Order - No.: BE8144-V ENGLISH
1 of 10
Page

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SBA141 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for BRINKMANN PUMPS SBA141 Series

  • Page 1 BE8144-V Operating Instructions (Translation of original) BRINKMANN-Vertical End Suction Pumps SBA141...143-V and SBF125-V Brinkmann Pumpen K. H. Brinkmann GmbH & Co. KG Friedrichstraße 2 D-58791 Werdohl Tel.: +49-2392 / 5006-0 www.brinkmannpumps.de Fax.: +49-2392 / 5006-180 sales@brinkmannpumps.de Subject to change without prior notice. Order - No.: BE8144-V ENGLISH ©...
  • Page 2: Table Of Contents

    Brinkmann–Vertical End Suction Pumps Series SBA141...143-V and SBF125-V Contents 9 Trouble shooter’s guide ........6 Indication to the manual ........2 Description of product ........2-3 10 Spare part ............7 Safety instructions .......... 3-4 11 Repair Instructions ........8-9 Transport and storage ........
  • Page 3: Safety Instructions

    Technical data Max. del. Max. del. Dimen- Weight Power Noise pressure volume sions 50 / 60 Hz level bar / spec. Type weight 1 l/min H mm h mm dBA / 50 Hz SBA141-V 32.5 0.63 0.725 SBA142-V 1.27 SBA143-V 3.95 1.95 SBF125-V...
  • Page 4: Transport And Storage

    Safety instructions relevant for operation 5 Installation and Connection • If hot or cold machine components involve Mechanical installation hazards. they must be guarded against acci- The pumps must be properly fastened. The pipe- dental contact. work must be installed so that no distortion of the •...
  • Page 5: Start Up / Shut Down

    Electric wiring 6 Start up / Shut down Start up ATTENTION Switch off at the mains. All service work must be carried out by quali- After connection the electrical wires, close the fied service personnel. Pump must be discon- terminal box. Briefly start the motor (max. 30 sec.) nected from the power source and all rotating and check the rotation according to the arrow on parts must stand still.
  • Page 6: Servicing And Maintenance

    8 Servicing and Maintenance Pumps with double mechanical seal (-GD) Pumps with double mechanical seal (-GD) are ATTENTION identified by the letters GLRD stamped in on the motor side of the pump foot and must include an oil The surface of the motor must be kept free of dirt. receiver with a capacity of 0.24 litres.
  • Page 7: Spare Part

    10 Spare part 10.1 Spare part list for Brinkmann Horizontal SBA141...143-V and SBF125-V End-Suction Pumps Series Item Description Stator with terminal board Motor flange End shield Terminal box Retaining ring DIN 472 Retaining ring DIN 471 Fan cover Ball bearing up to 1.1 kW DIN 625 Ball bearing 1.7 kW DIN 628...
  • Page 8: Repair Instructions

    10.2 Indications to the spare part order 11)Loosen the Socket head cap screws (17) and remove the pump body (50). Spare parts are available from the supplier. Standard commercially available parts are to be 12)Remove circlip (25) and the m ech.
  • Page 9: Disposal

    − Tighten the shaft clamp ( 35 mm) for 11.2 Dismantling the insert shaft SBA143-V Use a torque screwdriver to tighten each screw first with 2 Nm then with 3.5 Nm and finally with 5 Nm (in a clockwise direction again) Repeat the last turn (with 5 Nm) 3 times.
  • Page 10: Ec Declaration Of Conformity

    13 EC declaration of conformity DEUTSCH / ENGLISH /FRANÇAIS / ESPAÑOL EG-Konformitätserklärung EC declaration of conformity / Déclaration de conformité CE / Declaración de conformidad CE Hersteller / Manufacturer / Constructeur / Fabricante Brinkmann Pumpen, K. H. Brinkmann GmbH & Co. KG Friedrichstraße 2, D-58791 Werdohl Produktbezeichnung / Product name / Désignation du produit / Designación del producto Vertikale Blockpumpen / Vertical End-Suction Pumps / Pompes verticales monobloc / Bombas verticales mono-...

This manual is also suitable for:

Sba141-vSba142-vSba143-vSbf125-v

Table of Contents